Feasibility study of the neutron dose for real-time image-guided proton therapy: A Monte Carlo study

Abstract

Two full rotating gantries with different nozzles (multipurpose nozzle with MLC, scanning dedicated nozzle) for a conventional cyclotron system are installed and being commissioned for various proton treatment options at Samsung Medical Center in Korea. The purpose of this study is to use Monte Carlo simulation to investigate the neutron dose equivalent per therapeutic dose, H/D, for X-ray imaging equipment under various treatment conditions. At first, we investigated the H/D for various modifications of the beamline devices (scattering, scanning, multi-leaf collimator, aperture, compensator) at the isocenter and at 20, 40 and 60 cm distances from the isocenter, and we compared our results with those of other research groups. Next, we investigated the neutron dose at the X-ray equipment used for real-time imaging under various treatment conditions. Our investigation showed doses of 0.07 ~ 0.19 mSv/Gy at the X-ray imaging equipment, depending on the treatment option and interestingly, the 50% neutron dose reduction was observed due to multileaf collimator during proton scanning treatment with the multipurpose nozzle. In future studies, we plan to measure the neutron dose experimentally and to validate the simulation data for X-ray imaging equipment for use as an additional neutron dose reduction method.

This is a preview of subscription content, access via your institution.

References

  1. [1]

    J. S. Kim et al., J. Korean Phys. Soc, 55, 1640 (2009).

    ADS  Article  Google Scholar 

  2. [2]

    J. S. Shin et al., Radiation Oncology Journal 29, 206 (2011).

    Article  Google Scholar 

  3. [3]

    D. W. Miller, Medical physics 22, 1943 (1995).

    ADS  Article  Google Scholar 

  4. [4]

    D. R. Olsen et al., Radiotherapy and Oncology 83, 123 (2007).

    Article  Google Scholar 

  5. [5]

    E. J. Hall, Int. J. Radiat. Oncol. Biol. Phys. 65, 1 (2006).

    ADS  Article  Google Scholar 

  6. [6]

    R. Macklis, Int. J. Radiat. Oncol. Biol. Phys. 66, 1593 (2006).

    Article  Google Scholar 

  7. [7]

    Y. Zheng et al., Phys. Med. Biol. 52, 4481 (2007).

    Article  Google Scholar 

  8. [8]

    S. Yonai et al., Medical physics 36, 4830 (2009).

    ADS  Article  Google Scholar 

  9. [9]

    X. Wang et al., Int. J. Radiat. Oncol. Biol. Phys. 76, 1563 (2010).

    Article  Google Scholar 

  10. [10]

    M. Yoon et al., Int. J. Radiat. Oncol. Biol. Phys. 77, 1477 (2010).

    Article  Google Scholar 

  11. [11]

    E. S. Diffenderfer et al., Medical physics 38, 6248 (2011).

    ADS  Article  Google Scholar 

  12. [12]

    S. Kim et al., Radiotherapy and oncology 98, 335 (2011).

    Article  Google Scholar 

  13. [13]

    Y. Zheng et al., Medical physics 39, 3484 (2012).

    ADS  Article  Google Scholar 

Download references

Author information

Affiliations

Authors

Corresponding author

Correspondence to Youngyih Han.

Rights and permissions

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

Kim, J.S., Shin, J.S., Kim, D. et al. Feasibility study of the neutron dose for real-time image-guided proton therapy: A Monte Carlo study. Journal of the Korean Physical Society 67, 142–146 (2015). https://doi.org/10.3938/jkps.67.142

Download citation

Keywords

  • Proton therapy
  • Monte-Carlo simulation
  • Neutron dose