Skip to main content
Log in

Sensitivity analysis of a wide-field telescope

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

We are developing three ground-based wide-field telescopes. A wide-field Cassegrain telescope consists of two hyperbolic mirrors, aberration correctors and a field flattener for a 2-degree field of view. The diameters of the primary mirror and the secondary mirror are 500 mm and 200 mm, respectively. Corrective optics combined with four lenses, a filter and a window are also considered. For the imaging detection device, we use a charge coupled device (CCD) which has a 4096 × 4096 array with a 9-µm2 pixel size. One of the requirements is that the image motion limit of the opto-mechanical structure be less than 1 pixel size of the CCD on the image plane. To meet this requirement, we carried out an optical design evaluation and a misalignment analysis. Line-of-sight sensitivity equations are obtained from the rigid-body rotation in three directions and the rigid-body translation in three directions. These equations express the image motions at the image plane in terms of the independent motions of the optical components. We conducted a response simulation to evaluate the finite element method models under static load conditions, and the result is represented by the static response function. We show that the wide-field telescope system is stiff and stable enough to be supported and operated during its operating time.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. H. Lee, Y-S. Jung, S-Y. Ryoo and Y-J. Kim, J. Optical Soc. Korea 15, 2 (2011).

    Google Scholar 

  2. Siemens Product Lifecycle Management Software Inc., NX Nastran Basic Dynamic Analysis User’s Guide, 2008.

    Google Scholar 

  3. Kodak Company, KAF-16801 Image sensor — Device performance specification, 2010.

    Google Scholar 

  4. R. N. Clark. Appl. Opt. 15,5, 1266 (1976).

    Article  ADS  Google Scholar 

  5. S. Magarill, Proc. SPIE 3786, 220 (1999).

    Article  ADS  Google Scholar 

  6. V. J. Wagner, R. Malnory and K. S. Ellis, in Proceedings of the Conference of MSC 1998 America Users’ Conference (Los Angeles, CA, October 5–9, 1998), Paper No. 2198.

  7. S. Lee, J. Lim, J. H. Jo, J. U. Lee, Y. W. Lee and I. K. Moon, J. Korean Phys. Soc. 60, 759 (2012).

    Article  ADS  Google Scholar 

  8. J. H. Lee, C. W. Lee, Y. Kim and J. Kim, J. Optical Soc. Korea 13, 2 (2009).

    Article  Google Scholar 

  9. P. Yoder, Opto-mechanical Systems Design, 2nd edition (Marcel Dekker, New York, 1993), Chapter 3.

    Google Scholar 

  10. H. Himelblau, D. L. Kern, J. E. Manning, A. G. Piersol and S. Rubin, Report, NASA-HDBK-7005, 2001.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ho Jin.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lim, J., Lee, S., Moon, I.K. et al. Sensitivity analysis of a wide-field telescope. Journal of the Korean Physical Society 63, 28–35 (2013). https://doi.org/10.3938/jkps.63.28

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.63.28

Keywords

Navigation