Abstract
Solid state nuclear track detectors (SSNTDs) are widely used to measure various types of ionizing radiation. Thus, studying the physical parameters of SSNTDs, such as the bulk etch rate, the track etching efficiency and detector sensitivity which could affect the registration efficiency, is important. This paper presents a simple technique used to study the dependence of those characteristic physical parameters of SSNTDs on the alpha-particle energy. The detector sensitivity and the alpha track diameter were found to decrease exponentially with increasing alpha-particle energy’s, which implies that the SSNTDs can be used as alpha-particle spectrometers. The bulk etch rates of the LR-115 and the CR-39 detectors were found to be 3.75 ± 0.21 µm h−1 and 1.72 ± 0.14 µm h−1, respectively. Moreover, the calibration coefficients of the LR-115 and the CR-39 detectors, placed in a diffusion cup with a fiberglass filter exposed to radon source inside a 50 L calibration chamber (supplied by Genitron, Germany), were found to be 0.036 ± 0.004 and 0.17 ± 0.03 [α-tracks cm−2 per (Bq m−3 day)], respectively.
Similar content being viewed by others
References
T. Yamauchi, Radiat. Meas. 36, 73 (2003).
M. A. Misdaq, Appl. Radiat. Isot. 59, 273 (2003).
D. Zhou, D. O’Sullivan, E. Semones, N. Zapp and E. R. Benton, Radiat. Meas. 44, 909 (2009).
R. L. Fleischer, P. B. Price and R. M. Walker, Nuclear Tracks in Solids, Principles and Applications (University of California Press, Berkeley, 1975).
A. F. Hafez and G. Somogyi, Radiat. Meas. 12, 697 (1986).
F. Leonardi, M. Caresana, M. d’Alessandro, R. Mishra, S. Tonnarini, R. Trevisi and M. Veschetti, Radiat. Meas. 44, 787 (2009).
V. Chavan, P. C. Kalsi and A. Mhatre, J. Radioanal. Nucl. Chem. 87, 273 (2011).
G. Somogyi, Atomki prepriat E/25 4001 Debrecen pf. 51 Hungary (1990).
D. Nikezic, P. Markovic and D. B. Uzarov, Health Phys. 62, 239 (1992).
P. B. Price and D. O’Sullivan, in Proceeding of 11th International Conference of Solid State Nuclear Track Detectors (Bristol, 1981), P. 929.
F. Malik, E. U. Khan, I. E. Qureshi, S. N. Husaini, M. Sajid, S. Karim and K. Jamil, Radiat. Meas. 35, 30 (2002).
G. M. Hassib, H. A. Amer, M. I. Hussien and E. Piesh, German-Egyptian Cooperation Scientific Research and Technological Development, Bureau 31 (1995).
S. A. Durrani and R. K. Bull, State Nuclear Track Detection: Principles, Methods and Applications (Pergamum Press, Oxford, 1987).
S. Matiullah Rehman, S. Rehman and W. Zaman, Radiat. Meas. 39, 337 (2005).
A. F. Hafez, A. S. Hussein and N. M. Rasheed, Appl. Radiat. Isot. 54, 291 (2001).
N. F. Santos, P. J. Iunes, S. R. Paulo, S. Guedes and J. C. Hadler, Radiat. Meas. 45, 823 (2010).
A. J. Khan, A. K. Varshney, R. Prasad, R. K. Tyagi and T. V. Ramachandran, Nucl. Tracks Radiat. Meas. 17, 497 (1990).
I. Avramović, R. Benderać, D. Velićković, S. Stanković and M. Kovaćević, Nucl. Tracks Radiat. Meas. 25, 607 (1995).
A. F. Saad, Radiat. Meas. 43, S463 (2008).
M. Urban, Nucl. Tracks Radiat. Meas. 12, 685 (1986).
Chang Bing, Nucl. Tracks Radiat. Meas. 22, 451 (1993).
M. Abo-Elmagd, M. Sc. Thesis, Ain Shams University, 1997.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Hassan, N.M., Hafez, A.F. Studying the physical parameters of a solid state nuclear track detector. Journal of the Korean Physical Society 63, 1713–1719 (2013). https://doi.org/10.3938/jkps.63.1713
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3938/jkps.63.1713