Abstract
The drift tube linac (DTL) is used to accelerate proton beams from 20 MeV to 100 MeV in the linear accelerator of the Proton Engineering Frontier Project (PEFP). The phase scan signature method is a common technique to determine the radio-frequency (rf) set point, including the rf amplitude and phase, in DTL tanks. In this work, we applied the phase scan method to the first tank of the PEFP’s DTL in order to study the procedure for determining the rf set point by using artificial experimental data generated by using the PARMILA code.
Similar content being viewed by others
References
T. L. Owens, M. B. Popovic, E. S. Mccrory, C.W. Schmidt and L. J. Allen, Part. Accel. 48, 169 (1994).
D. Jeon, in Proceedings of PAC2005 (Knoxville, TN, USA, May 16–20, 2005), p.2616.
A. Feschenko, S. Bragin, Y. Kiselev, L. Kravchuk, O. Volodkevich, A. Aleksandrov, J. Galambos, S. Henderson and A. Sheshlo, in Proceedings of PAC2005 (Knoxville, TN, USA, May 16–20, 2005), p. 3064.
G. Shen and M. Ikegami, Nucl. Instrum. Meth. A 598, 361 (2009).
G. Shen and M. Ikegami, Chin. Phys. C 33, 577 (2009).
D. Jeon, Nucl. Instrum. Methods Phys. Res., Sect. A 578, 379 (2007).
H. Takeda and J. H. Billen, LA-UR-98-4478, 1998.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jang, JH., Kwon, HJ. & Cho, YS. Study on the RF Set Point for the PEFP DTL by using a phase scan method. Journal of the Korean Physical Society 61, 1792–1796 (2012). https://doi.org/10.3938/jkps.61.1792