Skip to main content
Log in

Tomotherapy planning and image registration for planning CT image slice thickness for stereotactic radiosurgery

  • Published:
Journal of the Korean Physical Society Aims and scope Submit manuscript

Abstract

Tomotherapy (TomoTherapy, Inc., Madison, WI, USA) is a helical intensity modulated radiation therapy (IMRT) modality using rotational delivery of a fan beam like a CT scanner to deliver highly conformal radiation dose distributions in an intensity-modulated fashion. Tomotherapy can image guided radiation therapy (IGRT) using megavoltage computed tomography (MVCT). In this study, different CT slice thicknesses were acquired in order to evaluate the effect of CT slice thickness on tomotherapy planning and image registration for stereotactic body radio therapy (SBRT) or stereotactic radiosurgery (SRS) by using end-to-end (EtoE) phantom (Accuray, USA). EtoE phantom kilovoltage CT (KVCT) and MVCT images were acquired using CT (LightSpeed 16, GE, USA), and tomotherapy (Tomotherapy, USA), respectively. Reference planning target volumes (RPTV) in the EtoE phantom were contoured. The volume of the RPTV was 14.13 cc, and the CT image thicknesses were 2, 4, and 6 mm. CT images were planned based on the tomotherapy planning system (TPS), and all plans had the same constraints and iterations. The PTV volumes were 16.58 cc, 18.88 cc, and 20.28 cc in 2-, 4- and 6 mm planning KVCTs, respectively. The PTV volumes were 16.32, 18.00, and 22.04 cc in 2-, 4-, and 6 mm using MVCT, respectively. Heavy thickness planning of the CT slice overestimated the RPTV volume in TPS. Also, the heavy thickness MVCT image skipped target slice images. The target coverage of the treatment plans for different slice thicknesses was correlated with the tumor volume. At 10-Gy prescription dose of PTV, dose coverages of the reference planning target volume were 10.14, 10.25, and 10.27 Gy for 2-, 4-, and 6-mm slice thicknesses. Therefore, when radiosurgery is supplemented with tomotherapy, thin slice (<2 mm) planning should be done and MVCT images should be acquired

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. T. R. Mackie, J. Phys, Med. Biol. 51, 427 (2006).

    Article  Google Scholar 

  2. S. Yartsev, A. R. Dar and C. Woodford, Biomed. Imaging Intervention J. 3, 1 (2007).

    Google Scholar 

  3. J. Balog, T. Holmes and R. Vaden, Med. Phys. 33, 3939 (2006).

    Article  Google Scholar 

  4. I. J. Lee, J. S. Seong and C. G. Lee, Int. J. Radiat. Oncol. Biol. Phys. 73, 1517 (2009).

    Article  Google Scholar 

  5. K. M. Langen, S. L. Meeks and D. O. Poole, Phys. Med. Biol. 50, 4259 (2005).

    Article  Google Scholar 

  6. E. T. Soisson, P. W. Hoban and T. Kammerye, Med. Dosim. 36, 46 (2011).

    Article  Google Scholar 

  7. S. M. Goddu, S. Mucic and O. L. Pechenaya, Phys. Med. Biol. 54, 5663 (2009).

    Article  Google Scholar 

  8. S. H. Benedict, K. M. Yenice and D. Followill, Med. Phys. 37, 4078 (2010).

    Article  Google Scholar 

  9. J. Zhou, B. Uhl and K. Dewitt, Med. Dosim. 35, 12 (2010).

    Article  Google Scholar 

  10. T. Kron, G. Grigorov and E. Yu, Phys. Med. Biol. 49, 3675 (2004).

    Article  Google Scholar 

  11. M. K Kissick, J. Fenwik and J. A. James, Med. Phys. 32, 1414 (2005).

    Article  Google Scholar 

  12. D. C. Westerly, E. Soisson and Q. Chen, Int. J. Radiat. Oncol. Biol. Phys. 74, 1290 (2009).

    Article  Google Scholar 

  13. K. M. Langen, S. L. Meeks and D. O. Poole, Phys. Med. Biol. 50, 4259 (2005).

    Article  Google Scholar 

  14. J. Zhou, B. Uhl and K. Dewitt, Med. Dosim 12, 35 (2010).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Young-nam Kang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jung, JY., Kay, C.S., Son, S.H. et al. Tomotherapy planning and image registration for planning CT image slice thickness for stereotactic radiosurgery. Journal of the Korean Physical Society 60, 137–141 (2012). https://doi.org/10.3938/jkps.60.137

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.60.137

Keywords

Navigation