Abstract

We conducted a feasibility study using a total-variation minimization algorithm for image reconstruction in prospectively gated micro computed tomography (micro-CT). The total-variation (TV) minimization algorithm exploits the sparseness of the image’s gradient magnitude and can successfully reconstruct CT images from undersampled data for which conventional analytic reconstruction algorithms fail. We implemented the algorithm and applied it to sparsely-sampled data for a mouse by using a prospectively gated micro-CT system. The images were successfully reconstructed, and an image similarity index was quantitatively calculated with respect to the reference images reconstructed from fully-sampled data. Compared to a conventional image reconstruction algorithm, the TV-minimization algorithm substantially reduced image inaccuracy related to the image artifacts.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. E. L. Ritman, J. Cell. Biochem. 39, 116 (2002).

    Article  Google Scholar 

  2. N. L. Ford, M. M. Thomton and D. W. Holdsworth, Med. Phys. 30, 2869 (2003).

    Article  Google Scholar 

  3. S-C. Lee, H-K. Kim, I-K. Chun, M-H. Cho, S-Y. Lee and M-H. Cho, Phys. Med. Biol. 48, 4173 (2003).

    Article  Google Scholar 

  4. S. Cho, J. Bian, C. A. Pelizzari, C-T. Chen, T-C. He and X. Pan, Med. Phys. 34, 4923 (2007)

    Article  Google Scholar 

  5. D. Cavanaugh, E. Johnson, R. E. Price, J. Kurie, E. L. Travis and D. D. Cody, Mol. Imaging 3, 55 (2004).

    Article  Google Scholar 

  6. E. B. Walters, K. Panda, J. A. Bankson, E. Brown and D. D. Cody, Phys. Med. Biol. 49, 4163 (2004).

    Article  Google Scholar 

  7. L. A. Feldkamp, L. C. Davis and J. W. Kress, J. Opt. Soc. Am. A 1, 612 (1984).

    Article  ADS  Google Scholar 

  8. E. Candes, J. Romberg and T. Tao, IEEE Trans. Inf. Theory 52, 489 (2006).

    Article  MathSciNet  MATH  Google Scholar 

  9. E. Y. Sidky, C-M. Kao and X. Pan, J. X-Ray Sci. Technol. 14, 119 (2006).

    Google Scholar 

  10. E. Y. Sidky and X. Pan, Phys. Med. Biol. 53, 4777 (2008).

    Article  Google Scholar 

  11. K. Choi, J. Wang, L. Zhu, T-S. Suh, S. Boyd and L. Xing, Med. Phys. 37, 5113 (2010).

    Article  Google Scholar 

  12. J. Song, Q. H. Liu, G. A. Johnson and C. T. Badea, Med. Phys. 34, 4476 (2007).

    Article  Google Scholar 

  13. G. H. Chen, J. Tang and S. Leng, Med. Phys. 35, 660 (2008).

    Article  Google Scholar 

  14. C. T. Badea, S. M. Johnston, Y. Qi and G. A. Johnson, Phys. Med. Biol. 56, 3351 (2011).

    Article  Google Scholar 

  15. Z. Wang and A. Bovik, IEEE Signal Process. Lett. 9, 81 (2002).

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Seungryong Cho.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Min, J., Cho, G., Cho, S. et al. Sparse-view image reconstruction in prospectively gated micro-CT for fast and low-dose imaging. Journal of the Korean Physical Society 60, 1157–1160 (2012). https://doi.org/10.3938/jkps.60.1157

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3938/jkps.60.1157

Keywords

Navigation