Chinese Journal of Mechanical Engineering

, Volume 28, Issue 5, pp 994–998 | Cite as

Multiple measurement models of articulated arm coordinate measuring machines

Article
  • 96 Downloads

Abstract

The existing articulated arm coordinate measuring machines(AACMM) with one measurement model are easy to cause low measurement accuracy because the whole sampling space is much bigger than the result in the unstable calibration parameters. To compensate for the deficiency of one measurement model, the multiple measurement models are built by the Denavit-Hartenberg’s notation, the homemade standard rod components are used as a calibration tool and the Levenberg-Marquardt calibration algorithm is applied to solve the structural parameters in the measurement models. During the tests of multiple measurement models, the sample areas are selected in two situations. It is found that the measurement errors’ sigma value(0.083 4 mm) dealt with one measurement model is nearly two times larger than that of the multiple measurement models(0.043 1 mm) in the same sample area. While in the different sample area, the measurement errors’ sigma value(0.054 0 mm) dealt with the multiple measurement models is about 40% of one measurement model(0.137 3 mm). The preliminary results suggest that the measurement accuracy of AACMM dealt with multiple measurement models is superior to the accuracy of the existing machine with one measurement model. This paper proposes the multiple measurement models to improve the measurement accuracy of AACMM without increasing any hardware cost.

Keywords

articulated arm coordinate measuring machine multiple measurement models sample area measurement accuracy 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. [1]
    ZHANG Guoxiong. New progress of coordinate measuring technology [J]. Aviation Precision Manufacturing Technology, 2008, 44(3): 16–19. (in Chinese)Google Scholar
  2. [2]
    LARRY A. Competition rising in portable CMMs[J]. Quality Measurement Test and Inspection, 2002, 7: 18–22.Google Scholar
  3. [3]
    DONG Yude, LIU Daxin, ZHAO Han, et al. CAD model-based intelligent inspection planning for coordinate measuring machines [J]. Chinese Journal of Mechanical Engineering, 2011, 24(4): 567–583.MathSciNetCrossRefGoogle Scholar
  4. [4]
    ZHENG Dateng, DU Chengtao, HU Yonggang. Research on optimal measurement area of flexible coordinate measuring machines[J]. Measurement, 2012, 45(3): 250–254.CrossRefGoogle Scholar
  5. [5]
    WEI Lin, WANG Congjun. Coordinate transformation and parametric calibration of multi-joint articulated coordinate measuring machine [J]. Opto-Electronic Engineering, 2007, 34(5): 57–61. (in Chinese)Google Scholar
  6. [6]
    WANG Xueying, LIU Shugui, ZHANG Hongtao, et al. Error analysis of articulated arm flexible CMM[J]. Chinese Journal of Sensors and Actuators, 2007, 20(2): 435–438. (in Chinese)Google Scholar
  7. [7]
    JORGE S, BRAU A, VELAZQUEZ J, et al. A self-centering active probing technique for kinematic parameter identification and verification of articulated arm coordinate measuring machines[J]. Measurement Science and Technology, 2010, 21(5): 1–7.Google Scholar
  8. [8]
    ZHENG Dateng, FEI Yetai. Research on space error model of flexible coordinate measuring machine[J]. Journal of Mechnical Engineering, 2010, 46(10): 19–24. (in Chinese)CrossRefGoogle Scholar
  9. [9]
    HAMANA H, TOMINAGA M, OZAKI M, et al. Calibration of articulated arm coordinate measuring machine considering measuring posture[J]. Int. J. of Automation Technology, 2011, 5: 109–110.Google Scholar
  10. [10]
    JORGE S, AGUILAR J, YAGRE J, et al. Kinematic parameter estimation technique for calibration and repeatability improvement of articulated arm coordinate measuring machines[J]. Precision Engineering, 2008, 32(4): 251–268.CrossRefGoogle Scholar
  11. [11]
    JORGE Santolaria, ANAC Majarena, DAVID Samper, et al. Articulated arm coordinate measuring machine calibration by laser tracker multilateration[J]. The Scientific World Journal, 2014, 1: 1–11.Google Scholar
  12. [12]
    WANG Wen, LIN Keng, GAO Guanbin, et al. Eccentricity parameter identification of angle sensors for articulated arm CMMs [J]. Optics and Precision Engineering, 2010, 18(1): 135–142. (in Chinese)Google Scholar
  13. [13]
    FEKRIA R, FRANCOIS H, MIN G, et al. Methodology for the assessment of measuring uncertainties of articulated arm coordinate measuring machines[J]. Measurement Science and Technology, 2014, 25(12): 1–14.Google Scholar
  14. [14]
    TUOMO K, SAARINEN H, MATTILA J, et al. Calibration and compensation of deflections and compliances in remote handling equipment configurations[J]. Fusion Engineering and Design, 2011, 86(9): 2043–2046.Google Scholar
  15. [15]
    LENKA B. The method for solving kinematics of an industrial robot[J]. Applied Mechanics and Materials, 2013, 282: 274–281.CrossRefGoogle Scholar
  16. [16]
    YANG Xiaojun, LI Bing, ZHANG Donglai. Kinematics calibration of parallel kinematic machine using a developed double-ball bar gauge[J]. Key Engineering Materials, 2008, 243(8): 364–366.Google Scholar
  17. [17]
    GUERSEL A, BIJAN S. A systematic technique to estimate position errors for robot accuracy improvement using laser interferometry based sensing[J]. Mechanism and Machine Theory, 2005, 40(8): 879–906.MATHCrossRefGoogle Scholar
  18. [18]
    YE Shenghua, WANG Yi, REN Yongjie, et al. Calibration of robot kinematic parameters based on laser tracker[J]. Journal of Tianjin University, 2007, 40(2): 202–205. (in Chinese)Google Scholar
  19. [19]
    CHEN Zhenyu, FU Chusheng, LI Dehua. Genetics based calibration algorithm for structure parameters of multi-joints 3D scanner[J]. Infrared and Laser Engineering, 2003, 32(5): 535–538. (in Chinese)Google Scholar
  20. [20]
    WANG Xueying, LIU Shugui, ZHANG Hongtao, et al. Calibration technology of the articulated arm flexible CMM[J]. Key Engineering Materials, 2008, 381–382: 161–164.CrossRefGoogle Scholar
  21. [21]
    WANG Pingping, FEI Yetai, LIN Shenwang. Calibration technology of a flexible coordinate measuring arm[J]. Journal of Xi’an Jiaotong University, 2006, 40(3): 284–288. (in Chinese)Google Scholar
  22. [22]
    GAO Guanbin, WANG Wen, LIN Keng, et al. Parameter identification based on modified annealing algorithm for articulated arm CMMs[J]. Optics and Precision Engineering, 2009, 15(8): 2499–2505. (in Chinese)Google Scholar
  23. [23]
    CHENG Wentao, YU Liandong, FEI Yetai. Study on parameter identification algorithms for articulated arm coordinate measuring machine[J]. Journal of University of Science and Technology of China, 2011, 41(1): 45–49. (in Chinese)Google Scholar

Copyright information

© Chinese Mechanical Engineering Society and Springer-Verlag Berlin Heidelberg 2015

Authors and Affiliations

  1. 1.College of Mechanical & Electrical EngineeringJinggangshan UniversityJianChina

Personalised recommendations