Abstract
An intracranial stimulation unit which offers precise control of stimulus duration, frequency, and current is described. The unit generates a square wave stimulus output utilizing very inexpensive, easily constructed integrated circuitry.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Ervin, F. R., &Kenney, G. J. Electrical stimulation of the brain. In R. D. Myers (Ed.),Methods in psychobiology. New York: Academic Press, 1971. Pp. 233–237.
Lilly, J. C. Hughes, J. R., Alvord, E. C., Jr., &Galkin, T. W. Brief, noninjurious electric waveform for stimulation of the brain.Science, 1955,121, 468–469.
Mickle, W. A. The problem of stimulation parameters. In D. E. Sheer (Ed.),Electrical stimulation of the brain. Austin, Texas: The University of Texas Press, 1961. Pp. 64–67. 70.
Author information
Authors and Affiliations
Additional information
This research was supported in part by the Committee on Faculty Research of the Graduate School of the University of Mississippi.
An erratum to this article is available at http://dx.doi.org/10.3758/BF03202201.
Rights and permissions
About this article
Cite this article
Fridlund, A.J., Leberer, M.R. An inexpensive integrated circuit intracranial stimulator. Behavior Research Methods & Instrumentation 8, 21–23 (1976). https://doi.org/10.3758/BF03201657
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.3758/BF03201657