Advertisement

Behavior Research Methods & Instrumentation

, Volume 7, Issue 5, pp 459–463 | Cite as

A semi-automated system for biofeedback-assisted relaxation therapy

  • Alan T. Pope
  • Charles D. Gersten
Instrumentation & Techniques
  • 208 Downloads

Abstract

A semi-automated system is described for use in research in biofeedback-assisted muscular relaxation therapy. The system employs a cassette tape recorder for presentation of instructions and for program control signals, programming modules for timing and gating EMG feedback and EMG recording intervals, a Kodak Carousel programmer to interface the cassette recorder with the programming system, and an EMG processor wired for external timing of feedback and counting of averaged EMG activity. A description of the current functioning of the system is presented, along with possible extensions.

Keywords

Relaxation Therapy Systematic Desensitization Exercise Instruction Logic Control System Relaxation Interval 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. Budzynski, T. H., &Stoyva, J. M. An instrument for producing deep muscle relaxation by means of analog information feedback.Journal of Applied Behavior Analysis, 1969,2, 231–237.CrossRefPubMedGoogle Scholar
  2. Budzynski, T. H., Stoyva, J. M., &Adler, C. S. Feedback-induced muscle relaxation: Application to tension headache.Journal of Behavior Therapy and Experimental Psychiatry, 1970,1, 205–211.CrossRefGoogle Scholar
  3. Budzynski, T. H., Stoyva, J. M., Adler, C. S., &Mullaney, C. M. BMG biofeedback and tension headache. A controlled-outcome study.Psychosomatic Medicine, 1973,35, 484–496.PubMedGoogle Scholar
  4. Castflian, N. John, Jr. The modern mini-computer in laboratory automation.American Psychologist, 1975,30, 205–211.CrossRefGoogle Scholar
  5. Green, F., Walters, E., Green, A., &Murphy, G. Feedback technique for deep relaxation.Psychophysiology, 1969,6, 371–377.CrossRefPubMedGoogle Scholar
  6. Jacobson, E.Progressive relaxation. Chicago University of Chicago Press. 1938.Google Scholar
  7. Jacobson, E.Modern treatment of tense patients. Springfield, Ill: Charles C Thomas, 1970.Google Scholar
  8. Kadden, R. M. State notation and SKED: A general system for control and recording of behavioral experiments.Behavior Research Methods & Instrumentation, 1974,6, 167–170.Google Scholar
  9. Lang, P. J. The on-line computer in behavior therapy research.American Psychologist, 1969,24, 236–239.CrossRefPubMedGoogle Scholar
  10. Luthe, W. (Ed.),Autogenic therapy (5 volumes). New York: Grune & Stratton, 1969.Google Scholar
  11. Migler, B., &Wolpe, J. Automated self-desensitization: A case report.Behavior Research and Therapy, 1967,5, 133–135.CrossRefGoogle Scholar
  12. Raskin, M., Johnson, G., &Rondestvedt, J. W. Chronic anxiety treated by feedback-induced muscle relaxation.Archives of General Psychiatry, 1973,28, 263–367.PubMedGoogle Scholar
  13. Russell, R. K., &Sipich, J. F. Cue-controlled relaxation in the treatment of test anxiety.Journal of Behavior Therapy and Experimental Psychiatry, 1973,4, 47–49.CrossRefGoogle Scholar
  14. Sidowski, J. B. Instrumentation and computer technology: Applications and influences in modern psychology.American Psychologist, 1975,30, 191–196.CrossRefGoogle Scholar
  15. Snapper, A. G., &Kadden, R. M. Time-sharing in a small computer based on a behavioral notation system. In B. Weiss (Ed.),Digital computers in the behavioral laboratory. New York: Applcton-Century-Crofts, 1973Google Scholar
  16. Wickhamasekera, I. Instructions and EMG feedback in systematic desensitization: A case report.Behavior Therapy, 1972,3, 460–465.CrossRefGoogle Scholar
  17. Wolpe, J.The practice of behavior therapy. New York: Pergamon Press, 1969.Google Scholar

Copyright information

© Psychonomic Society, Inc. 1975

Authors and Affiliations

  • Alan T. Pope
    • 1
  • Charles D. Gersten
    • 1
  1. 1.FDR VA HospitalMontrose

Personalised recommendations