Abstract
Standard calculation of the torque transmitted by a magnetic end coupling is considered for a coupling that consists of two highly coercive permanent magnets (thickness 4.5 mm) made of samarium–cobalt alloy. The air gap between the magnets in the half-couplings is 5–20 mm. A correction factor is obtained for use in calculating the torque transmitted by a coupling based on paired thin magnets.
REFERENCES
Krasil’nikov, A.Ya., Determination of shear force of thin KS-25DTs high-coercive permanent magnets in magnetic systems and magnetic couplings, Vestn. Mashinostr., 2019, no. 1, pp. 29–32.
Krasil’nikov, A.Ya., Standard designs of magnetic systems and couplings, Vestn. Mashinostr., 2002, no. 7, pp. 35–37.
Krasil’nikov, A.Ya. and Krasil’nikov, A.A., Effect of high-coercive permanent magnet grade on the parameters of end magnetic clutch, Vestn. Mashinostr., 2012, no. 7, pp. 17–23.
Krasil’nikov, A.Ya. and Krasil’nikov, A.A., Torque calculation of the magnetic end coupling, Vestn. Mashinostr., 2006, no. 5, pp. 20–22.
Funding
This work was supported by ongoing institutional funding. No additional grants to carry out or direct this particular research were obtained.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The authors of this work declare that they have no conflicts of interest.
Additional information
Translated by B. Gilbert
Publisher’s Note.
Allerton Press remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
About this article
Cite this article
Krasil’nikov, A.Y., Krasil’nikov, A.A. & Taranov, D.V. Torque Transmitted by a Magnetic End Coupling Based on Paired Thin Rare-Earth Alloy Permanent Magnets. Russ. Engin. Res. 44, 323–326 (2024). https://doi.org/10.3103/S1068798X24700278
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.3103/S1068798X24700278