Abstract
The output pressure of a plunger pump is studied experimentally as a function of the productivity. The corresponding empirical formula is derived.
Similar content being viewed by others
References
Xing, M.M., Dong, S.M., Tong, Z.X., et al., Dynamic simulation and efficiency analysis of beam pumping system, J. Cent. South Univ. (Engl. Ed.), 2015, vol. 22, no. 9, pp. 3367–3379.
Zhenyu, X., Xuhong, M., and Hai, Z., The research on pulsation of pump pressure in water mist system, Phys. Procedia, 2015, vol. 66, pp. 73–76.
Bai, Y., Fan, L., Ma, X., et al., Prediction model of the fuel injection pressure rise rate for an electronic unit pump, J. Harbin Eng. Univ., 2015, vol. 36, no. 7, pp. 932–937.
Weir SPM general catalog. https://www.global.weir.
LEWA ecoflow packed plunger-metering pump. http://www.lewa.com.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © N.L. Velikanov, V.A. Naumov, S.I. Koryagin, 2018, published in Vestnik Mashinostroeniya, 2018, No. 3, pp. 25–27.
About this article
Cite this article
Velikanov, N.L., Naumov, V.A. & Koryagin, S.I. Characteristics of Plunger Pumps. Russ. Engin. Res. 38, 428–430 (2018). https://doi.org/10.3103/S1068798X18060175
Published:
Issue Date:
DOI: https://doi.org/10.3103/S1068798X18060175