Abstract
Seismic tests of full-scale mockups of fuel assemblies from the VVER-1000 reactor permit the determination of the transfer characteristics between the stimulus (acceleration of the supports) and the response of the fuel assemblies. No resonant responses of the fuel assemblies to seismic loads are observed.
Similar content being viewed by others
References
Troyanov, V.M., Likhachev, Yu.I., and Folomeev, V.A., Seismic Calculations for the Active Zone of the VVER-1000 Reactor, Izv. Vyssh. Uchebn. Zaved., Yad. Energ., 2002, no. 3, pp. 26–33.
Standards for Strength Calculations of Nuclear-Plant Equipment and Pipelines: PNAE G-7-002-86, Moscow: Energoatomizdat, 1989, pp. 478–504.
Author information
Authors and Affiliations
Corresponding author
Additional information
Original Russian Text © Yu.N. Drozdov, M.A. Tananov, E.P. Osipova, T.I. Nazarova, V.V. Makarov, A.V. Afanas’ev, V.V. Abramov, 2012, published in Vestnik Mashinostroeniya, 2012, No. 3, pp. 52–57.
About this article
Cite this article
Drozdov, Y.N., Tananov, M.A., Osipova, E.P. et al. Seismic tests of fuel assemblies. Russ. Engin. Res. 32, 244–250 (2012). https://doi.org/10.3103/S1068798X12030094
Published:
Issue Date:
DOI: https://doi.org/10.3103/S1068798X12030094