Criteria for Assessing the Severity of Short-Circuit Faults for Choosing Controlling Actions of Emergency Automation

  • Published:
Russian Electrical Engineering Aims and scope Submit manuscript

Abstract—The transient stability of power engineering systems depends on the severity of short-circuit (SC) faults, generator load in the prefault mode, and postemergency conditions. This paper considers the criteria for assessing the severity of SC faults for choosing controlling actions to prevent violations in transient stability and proposes the most representative parameters for automatically ranking various kinds of SC by severity.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.

Similar content being viewed by others

REFERENCES

  1. Berkovich, M.A., Komarov, A.N., and Semenov, V.A., Osnovy avtomatiki energosistem (Fundamentals of Automatics of Power Sistems), Moscow: Energoizdat, 1974.

  2. Iof’ev, B.I., Avtomaticheskoe avariinoe upravlenie moshchnost’yu energosistem (Automatic Emergency Power Control of Power Systems), Moscow: Energiya, 1974.

  3. STO 59012820.29.020.004-2018. Releinaya zashchita i avtomatika. Avtomaticheskoe protivoavariinoe upravlenie rezhimami energosistem. Protivoavariinaya avtomatika. Normy i trebovaniya (STO 59012820.29.020.004-2018. Relay Protection and Automation. Automatic Emergency Control of Power System Modes. Emergency Automation of Power Systems. Norms and Requirements), Moscow: Edinaya Energ. Sist., 2018.

  4. Gurevich, Yu.E., Libova, L.E., and Okin, A.A., Raschety ustoichivosti i protivoavariinoi avtomatiki v energosistemkah (Calculation of Resistance and Emergency Automatics in Power Systems), Moscow: Energoatomizdat, 1990.

  5. Osnovy elektrotekhniki (Principles of Electrical Engineering), Krug, K.A., Ed., Moscow: Gosenergoizdat, 1952.

    Google Scholar 

  6. Ter-Gazaryan, G.N., Nesimmetrichnyi rezhim raboty gidrogeneratorov (Asymmetric Operation Mode of Hydrogenerators), Moscow: Gosenergoizdat, 1956.

  7. Lyubarsky, D.R., Programmno-tekhnicheskie sredstva protivoavariinogo upravleniya lokal’nogo urovnya (Software and Hardware for Local Emergency Control), Moscow: Energoatomizdat, 2006.

  8. Lyubarsky, D.R., The stabile functioning of relay protection devices and emergency automatics in electromagnetic and electromechanical transients, Doctoral (Eng.) Dissertation, Ivanovo, 2007.

  9. Maslennikov, V.A., Calculation of short-circuit currents in time and their analysis in electric power systems with a high concentration of generating equipment, Cand. Sci. (Eng.) Dissertation, Leningrad: Leningr. Polytech. Inst., 1984.

  10. Vazhnov, A.I., Perekhodnye protsessy v mashinakh peremennogo toka (Transient Processes in AC Machines), Leningrad: Energiya, 1980.

  11. Gluskin, I.Z. and Iof’ev, B.I., Protivoavariinaya avtomatika v energosistemakh (Emergency Automatics in Power Systems), Moscow: Znak, 2011, vol. 2.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to D. R. Lyubarsky.

Additional information

Translated by S. Kuznetsov

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Lyubarsky, D.R., Tuzlukova, E.V. Criteria for Assessing the Severity of Short-Circuit Faults for Choosing Controlling Actions of Emergency Automation. Russ. Electr. Engin. 91, 268–273 (2020). https://doi.org/10.3103/S1068371220040057

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068371220040057

Keywords:

Navigation