Abstract

The use of rigid noncorona busbars with the air insulation, gas-filled current leads, and current leads with the polymeric insulation to connect various high-voltage elements at plants and substations allows providing a decrease in the electric energy losses, increase in reliability and safety of operation, as well as improving the ecological situation at the plants and substations. Compactness of the busbars is provided due to the use of new insulation media (first and foremost, electrically high-strength gases and polymeric dielectrics), as well as improvement of the technology of production and use of these materials. At present, various types of high-voltage current leads are used: shielded air busbars, busbars with the cast polymeric insulation, and sealed shielded current leads with the basic high-strength gas insulation. Engineering solutions in which insulation media with low dielectric permeability are used and the buses are made noncorona with rated operating voltage are applied to reduce the losses in the busbars.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Irish Standard EN 50181:2010-04: Plug-in Type Bushings above 1 kV up to 52 kV and from 250 A to 2.50 kA for Equipment other Than Liquid Filled Transformers, Dublin: Natl. Stand. Authority Ireland, 2010.

  2. Varivodov, V.N., Development of sealed gas-insulated transmission lines for 110–1150 kV, Energoekspert, 2014, no.2.

  3. Sato, J., Kinoshita, S., Sakaguchi, O., Miyagawa, M., Shimizn, T., and Homma, M., Solid insulated switchgear and investigation of its mechanical and electrical reliability, Electr. Eng. Jpn., 2011, vol. 174, no.4.

    Google Scholar 

  4. Varivodov, V.N., Kovalev, D.I., Krupenin, N.V., and Khrenov, S.I., Development of high voltage and extra high voltage switchgears, Elektroenergiya. Peredacha Raspred., 2017, no. 1 (40).

    Google Scholar 

  5. Gautschi, D., Ficheux, A., Walter, M., and Vuachet, J., Application of a Fluoronitrile Gas in GIS and GIL as an Environmental Friendly Alternative to SF6, CIGRE Report B3-106, Paris: Cons. Int. Grands Réseaux Électriques, 2016.

    Google Scholar 

  6. Diggelmann, T., Tehlar, D., and Mueller, P., 170 kV Pilot Installation with a Ketone Based Insulation Gas with First Experience from Operation in the Grid, CIGRE Report B3-105, Paris: Cons. Int. Grands Réseaux Électriques, 2016.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. N. Varivodov.

Additional information

Original Russian Text © V.N. Varivodov, D.I. Kovalev, N.V. Krupenin, S.I. Khrenov, 2018, published in Elektrotekhnika, 2018, No. 5, pp. 11–17.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Varivodov, V.N., Kovalev, D.I., Krupenin, N.V. et al. Busbars for the Switchgears and Internal Connections of the Power Plants and 6- to 750-kV Substations. Russ. Electr. Engin. 89, 298–303 (2018). https://doi.org/10.3103/S1068371218050127

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068371218050127

Keywords

Navigation