A new PMU based power swing detector to prevent mal-operation of distance relay

  • Published:
Russian Electrical Engineering Aims and scope Submit manuscript

Abstract

In conventional transmission line protection, a distance relay is used to provide the primary as well as remote backup protection. The voltage and current phasors measurement needed by the distance relay for determining the impedance may be affected by the power disturbances such as power swing. Consequently, this power swing may cause mal-operation of Zone three distance relays which in turn may affect on the reliability of the whole protective scheme. To mitigate these effects and hence improve the relay reliability, this work proposes a new real-time power swing detector using phasor measurement units for blinding the distance relay only during this transient disturbance. However, this developed detector will not block relay when the power swing accompanied with faults. To validate the present work, the performance of developed enhanced distance relay is tested by signals generated by Simulink/MATLAB simulator under different conditions. The test results show that this proposed scheme provides good discrimination between the transient currents and the fault current which in turn it may contribute in enhancing the reliability of Distance relay.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Power Swing and out-of-step consideration on transmission lines, Report, Power System Relaying Committee of the IEEE Power Engineering Society, 2005, no. IEEE PSRC WGD6.

  2. Bentarzi, H., Ouadi, A., Chafai, M., and Zitouni, A., Distance protective system performance enhancement using optimized digital filter, Proc. CSECS’11 10th WSEAS Int. Conf. on Circuits, Systems, Electronics, Control and Signal Processing, Sofia, 2011, pp. 29–31.

    Google Scholar 

  3. Mechraoui, A., and Thomas, D.W.P., A new blocking principle with phase and earth fault detection during fast power swings for distance protection, IEEE Trans. Power Delivery, 1995, vol. 10, no. 3, pp. 1242–1248.

    Article  Google Scholar 

  4. Jonsson, M. and Daalder, J., A new protection scheme to prevent mal-trips due to power swings, Proc. IEEE/PES Transmission and Distribution Conf., 2001, vol. 2, pp. 724–729.

    Google Scholar 

  5. Lin, X., Gao, Y., and Liu, P., A fast unblocking scheme for distance protection to identify symmetrical fault occurring during power swings, IEEE Trans. Power Del., 2008, vol. 1, pp. 73–77.

    Article  Google Scholar 

  6. Su, B., Dong, X.Z., Bo, Z.Q., Sun, Y.Z., Caunce, B.R.J., Tholomier, D., and Apostolov, A., Fast detector of symmetrical fault during power swing for distance relay, IEEE Power Eng. Soc. Gen. Meet., 2005, vol. 2, pp. 1836–1841.

    Google Scholar 

  7. Jiao, S., Bo, Z., Liu, W., and Yang, Q., New principles to detect faults during power swing, Proc. 7th IEE Int. Conf. on Developments in Power Systems Protection, 2001, pp. 515–518.

    Google Scholar 

  8. Chaplygin, E.E., Astashev, M.G., and Rasuli, K.V., Use of active sources of reactive power for power-flow control in electrical networks, Russ. Electr. Eng., 2013, vol. 84, no. 12, pp. 674–679.

    Article  Google Scholar 

  9. Rao, J.G. and Pradhan, A.K., Differential power-based symmetrical fault detection during power swing, IEEE Trans. Power Delivery, 2012, vol. 27, no. 3, pp. 1557–1564.

    Article  Google Scholar 

  10. Sachdev, M.S. and Baribeau, M.A., A new algorithm for digital impedance relay, IEEE Trans. Power Apparatus Syst., 1979, vol. 98, pp. 2232–2240.

    Article  Google Scholar 

  11. Ouadi, A., Bentarzi, H., and Maun, J.C., A new computer based phasor measurement unit framework, Proc. 6th Int. Conf. SDD’09, Djerba, 2009, pp. 1–6.

    Google Scholar 

  12. Ouadi, A., Bentarzi, H., and Maun, J.C., Phasor measurement unit reliability enhancement using real-time digital filter, Int. J. Circuits, Syst. Signal Processing, 2011, vol. 5, no. 5, pp. 1–8.

    Google Scholar 

  13. Panfilov, D.I., Ryvkin, A.A., and Shimina, A.O., A way to measure power-quality indices in devices for monitoring processes that take place in overhead power-transmission lines, Russ. Electr. Eng., 2014, vol. 85, no. 6, pp. 345–349.

    Article  Google Scholar 

  14. Isaksson, A., Digital protective relaying through recursive least-squares identification, IEE Proc. Part C: Generat. Transmission Distribut., 1988, vol. 135, pp. 441–449.

    Google Scholar 

  15. Phadke, A.G., Hlibka, T., and Ibrahim, M., A digital computer system for EHV substation: analysis and field tests, IEEE Trans. Power Apparat. Syst., 1976, vol. PAS-95, pp. 291–301.

    Google Scholar 

  16. Lotfifard, S., Faiz, J., and Kezunovic, M., Detection of symmetrical faults by distance relays during power swings, IEEE Trans. Power Delivery, 2010, vol. 25, no. 1, pp. 81–87.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to H. Bentarzi.

Additional information

The article is published in the original.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ouadi, A., Bentarzi, H. & Chafai, M. A new PMU based power swing detector to prevent mal-operation of distance relay. Russ. Electr. Engin. 87, 572–578 (2016). https://doi.org/10.3103/S1068371216100059

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068371216100059

Keywords

Navigation