Abstract
Questions of determination and analysis of elasticity for a contact system from the perspective of qualitative current collection supply at high speeds are considered. To improve the coefficient of elastic uniformity, it is necessary to increase the tension of a contact wire and use modern devices for compensation of tension and vibration damping of a catenary. This should proceed to determination of spatial elasticity for a catenary.
Similar content being viewed by others
References
Pravila ustroistva i tekhnicheskoi ekspluatatsii kontaktnoi seti elektrifitsirovannykh zheleznykh dorog no. TsE-868 (Standards for Creating and Exploitation the Aerial Contact Wire for Electrified Railways no. TsE-868), Moscow: Transizdat, 2002.
Belyaev, I.A., Mikheev, V.P., and Shiyan, V.A., Tokos”em i tokopriemniki elektropodvizhnogo sostava (Current Collection and Current Receivers for Electrical Rolling Stock), Moscow: Transport, 1976.
Belyaev, I.A., Ustroistvo i obsluzhivanie kontaktnoi seti pri vysokoskorostnom dvizhenii (Construction and Service of Aerial Contact Wire under High-Speed Traffic), Moscow: Transport, 1989.
Fraifel’d, A.V. and Brod, G.N., Proektirovanie kontaktnoi seti (The Way to Design an Aerial Contact Wire), Moscow: Transport, 1991.
Mikheev, V.P., Kontaktnye seti i linii peredachi (Aerial Contact Wires and Power Lines), Moscow: Marshrut, 2003.
Mochinaga, Y., Quarterly Report of RTRI, 2000, no. 4, pp. 144–147.
Additional information
Original Russian Text © V.A. Zagorskii, V.F. Put’ko, R.F. Nasretdinov, 2013, published in Elektrotekhnika, 2013, No. 6, pp. 57–59.
About this article
Cite this article
Zagorskii, V.A., Put’ko, V.F. & Nasretdinov, R.F. Analysis of contact system elasticity. Russ. Electr. Engin. 84, 349–351 (2013). https://doi.org/10.3103/S1068371213060126
Received:
Published:
Issue Date:
DOI: https://doi.org/10.3103/S1068371213060126