Abstract
It is established that, at OAO ZSMK, the moisture content in the flotational concentrate is reduced by 4.5% when dehydrating the cake using Andritz vacuum filters rather than Ukraina-80 filters. The content of solid matter in the filtrate is reduced by a factor of four. Extraction of large-grain slurry from the supply to the vacuum filters is more complete, with corresponding reduction in the content of >0.5 mm classes (by 4.1%) and 0.06–0.50 mm classes (by 1.8%) in the filtrate. The loss of final product with the filtrates is reduced by 0.3%; the total power consumption of the vacuum-pump drives is reduced by 826 kW.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Original Russian Text © M.G. Fon, A.A. Sheffer, M.M. Naimark, Yu.V. Porshneva, 2008, published in Koks i Khimiya, 2008, No. 10, pp. 43–44.
About this article
Cite this article
Fon, M.G., Sheffer, A.A., Naimark, M.M. et al. Reconstruction of the flotation and filtration department in the coal-enrichment shop at OAO ZSMK. Coke Chem. 51, 414–415 (2008). https://doi.org/10.3103/S1068364X08100086
Published:
Issue Date:
DOI: https://doi.org/10.3103/S1068364X08100086