EXPERIMENTAL STUDY OF THE TARGET MOTION EFFECT ON THE DOSE DISTRIBUTION IN SPOT-SCANNING BEAM PROTON THERAPY

  • Published:
Bulletin of the Lebedev Physics Institute Aims and scope Submit manuscript

An Erratum to this article was published on 01 February 2023

This article has been updated

Abstract

This paper presents the experimental results on the intrafractional motion effect on dose distributions in a target in the context of spot-scanning beam proton therapy. The evaluation is performed by a qualitative analysis of the structure and shape of dose distributions and a quantitative analysis of the average dose and dose homogeneity within the region of interest for various motion parameters and acceleration cycles. The results show that intrafractional motion leads to a significant distortion of the dose field shape and structure. Distortions appear as hot and cold spots (overdosing and underdosing areas, respectively) dose field spread along the motion trajectory. These effects are reflected in a 16% reduction in the mean dose in the region of interest and dose homogeneity from 96.7 to 75.5% as the motion amplitude increases from 0 to 10 mm. In this case, the level of distortions weakly depends on time parameters of motion and the accelerator cycle. The observed effects lead to an efficiency degradation of proton therapy in the treatment of moving tumors; therefore, the use of such motion compensation methods as rescanning, gating, tracking, and their combinations is necessary for clinical practice.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1.
Fig. 2.
Fig. 3.

Similar content being viewed by others

Change history

REFERENCES

  1. Chernyaev, A.P., Klenov, G.I., Bushmanov, A.Yu., Pryanichnikov, A.A., Belikhin, M.A., and Lykova, E.N., Proton accelerators for radiation therapy, Med. Radiol. Radiat. Saf., 2019, vol. 64, no. 2, pp. 11–22. https://doi.org/10.12737/article_5ca5a0173e4963.18268254

    Article  Google Scholar 

  2. Kubiak, T., Particle therapy of moving targets – the strategies for tumor motion monitoring and moving targets irradiation, Br. J. Radiol., 2016, vol. 89, no. 1066, p. 20150275. https://doi.org/10.1259/bjr.20150275

  3. Trnková, P. et al., Clinical implementations of 4D pencil beam scanned particle therapy: Report on the 4D treatment planning workshop 2016 and 2017, Phys. Med., 2018, vol. 54, pp. 121–130. https://doi.org/10.1016/j.ejmp.2018.10.002

    Article  Google Scholar 

  4. Bert, C. et al., Scanned carbon beam irradiation of moving films: comparison of measured and calculated response, Radiat. Oncol., 2012, vol. 7, p. 55. https://doi.org/10.1186/1748-717X-7-55

  5. Bert, C. et al., Quantification of interplay effects of scanned particle beams and moving targets, Phys. Med. Biol., 2008, vol. 53, no. 9, p. 2253. https://doi.org/10.1088/0031-9155/53/9/003

    Article  Google Scholar 

  6. Balakin, V.E., Belikhin, M.A., Pryanichnikov, A.A., Shemyakov, A.E., and Strelnikova, N.S., Clinical application of new immobilization system in seated position for proton therapy, The 2nd International Symposium on Physics, KnE Energy/Engineering and Technologies for Biomedicine, 2018, pp. 45–51. https://doi.org/10.18502/ken.v3i2.1790

  7. Pryanichnikov, A.A., Sokunov, V.V., and Shemyakov, A.E., Some results of the clinical use of the Proton Therapy Complex “Prometheus,” Phys. Part. Nucl. Lett., 2018, vol. 15, no. 7, pp. 981–985. https://doi.org/10.1134/S1547477118070592

    Article  Google Scholar 

  8. Balakin, V.E., Bazhan, A.I., Alexandrov, V.A., Chashurin, V.I., Lunev, P.A., Pryanichnikov, A.A., Shemyakov, A.E., Belikhin, M.A., and Shestopalov, A.I., Updated status of Protom synchrotrons for radiation therapy, Proc. RuPAC'21, 2021, pp. 120–123. https://doi.org/10.18429/JACOW-RUPAC2021-FRB05

  9. Siksin, V.V., Ryabov, V.A., and Shemyakov, A.E., Registration of Bragg peaks in scanning mode of a target with a low-intensity proton beam from the PROMETEUS medical accelerator, Bull. Lebedev Phys. Inst., 2021, vol. 48, no. 12, pp. 16–21.

    Article  Google Scholar 

  10. Siksin, V.V. and Shemyakov, A.E., Measurements of the Bragg peak depth by a PPC-40 ionization chamber and a digital imaging detector, Bull. Lebedev Phys. Inst., 2020, vol. 47, no. 9, 285–289. https://doi.org/10.3103/S1068335620090055

    Article  ADS  Google Scholar 

  11. Wang, N. et al., Evaluation and comparison of New 4DCT based strategies for proton treatment planning for lung tumors, Radiat. Oncol., 2013, vol. 8, p. 73. https://doi.org/10.1186/1748-717X-8-73

Download references

Funding

This study was supported within the Federal Scientific and Technical program no. 075-15-2021-1347 (October 5, 2021) by the Ministry of Science and Higher Education of the Russian Federation “Development of new technologies for diagnostics and beam therapy of socially significant diseases by proton and ion beams using binary nuclear methods,” as well as technically supported by the Protom Ltd.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. A. Belikhin.

Ethics declarations

The authors declare that they have no conflicts of interest.

Additional information

Translated by A. Kazantsev

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Belikhin, M.A., Grigoryeva, M.S., Zavestovskaya, I.N. et al. EXPERIMENTAL STUDY OF THE TARGET MOTION EFFECT ON THE DOSE DISTRIBUTION IN SPOT-SCANNING BEAM PROTON THERAPY. Bull. Lebedev Phys. Inst. 49, 132–136 (2022). https://doi.org/10.3103/S1068335622050025

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S1068335622050025

Keywords:

Navigation