Skip to main content
Log in

Performance analysis of the recording system of nonlocal biomechanical signals

  • Published:
Radioelectronics and Communications Systems Aims and scope Submit manuscript

Abstract

This study presents the performance analysis results of biotechnical system for recording nonlocalized biomechanical signals. The circuits for simulating the impact of the pressing force (applied to the body surface) on the input of signal transducer were considered both in the absence and in the presence of a supporting surface of transducer. The sensor design was shown to influence the reduction level of the impact of the pressing force applied to the body resulting in the specific effect on the transducer input. In addition, the effect of the sensitivity loss of the recording channel of nonlocal biomechanical signals on the reduction level was also evaluated.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. S. Datta, B. H. Kodali, S. Segal, Obstetric Anesthesia Handbook (Springer Science + Business Media, LLC, 2010), 470 p.

    Book  Google Scholar 

  2. G. A. Macones, G. D. Hankins, C. Y. Spong, J. Hauth, T. Moore, “The 2008 National Institute of Child Health and Human Development workshop report on electronic fetal monitoring: update on definitions, interpretation, and research guidelines,” Obstet. Gynecol. 112, No. 3, 661 (Sept. 2008), DOI: 10.1097/AOG.0b013e3181841395.

    Article  Google Scholar 

  3. US Patent No. 0310710 A1 (21 Nov. 2013).

  4. A. A. Smerdov, Ye. V. Storchun, Biomedical Measuring Converters (Kalvariia, Lviv, 1997) [in Ukrainian].

    Google Scholar 

  5. S. G. Odintsov, “Measurement error analysis of local oscillations of the human body surface using electric analogies,” Cand. Sci. (Eng.) Dissertation (Moscow, 1991).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to E. I. Yakovenko.

Additional information

Original Russian Text © E.V. Storchun, E.I. Yakovenko, 2016, published in Izvestiya Vysshikh Uchebnykh Zavedenii, Radioelektronika, 2016, Vol. 59, No. 8, pp. 60–64.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Storchun, E.V., Yakovenko, E.I. Performance analysis of the recording system of nonlocal biomechanical signals. Radioelectron.Commun.Syst. 59, 375–378 (2016). https://doi.org/10.3103/S0735272716080070

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.3103/S0735272716080070

Navigation