ANSYS Fluent CFD Modeling of Solar Air-Heater Thermoaerodynamics

  • D. I. Pashchenko
Solar Power Plants and Their Application

Abstract

Numerical modeling of thermal and aerodynamic processes taking place in a solar air heater with light-absorbing L-shaped fins is performed. The study is carried out by means of an ANSYS Fluent Solver with an integrated solar calculator for the city of Samara, Russia. The influence of the design (the step between the fins) and technological variables (the Reynolds number) on heat-exchange processes and flow aerodynamics was established during the CFD analysis. Pictorial contours are determined for the velocity distribution, pressure, and other characteristics of the airflow in the solar air-heater box. Thermoaerodynamic characteristics and effective values of technological parameters for the effective use of a solar air heater are studied. The maximum thermoaerodynamic characteristic for the solar air heater with a finned lightabsorbing surface is 1.91 for Re = 1500, and the minimum test fin pitch is 30 mm.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Brit. Petroleum, BP Statistical Review of World Energy June 2016, London, UK: British Petroleum, 2016.Google Scholar
  2. 2.
    Saginov, L.D., Defects localization research in photovoltaic cells: methods and devices, Appl. Sol. Energy, 2016, vol. 52, no. 3, pp. 201–204.CrossRefGoogle Scholar
  3. 3.
    Hans, R., Kaushik, S.C., and Manikandan, S., Experimental study and analysis on novel thermo-electric cooler driven by solar photovoltaic system, Appl. Sol. Energy, 2016, vol. 52, no. 3, pp. 205–210.CrossRefGoogle Scholar
  4. 4.
    Eswaramoorthy, M., Thermal performance of V-trough solar air heater with the thermal storage for drying applications, Appl. Sol. Energy, 2016, vol. 52, no. 4, pp. 245–250.CrossRefGoogle Scholar
  5. 5.
    Maiorov, V.A. and Trushevskii, S.N., Study of thermal characteristics of a heating module with parabolic trough concentrator and linear wedge-like photoelectric receiver, Appl. Sol. Energy, 2016, vol. 52, no. 4, pp. 290–294.CrossRefGoogle Scholar
  6. 6.
    Avezova, N.R. and Avezov, R.R., A procedure for accelerated determination of main heat engineering parameters of flat-plate solar collectors for heating of a heat transfer fluid, Appl. Sol. Energy, 2016, vol. 52, no. 2, pp. 93–96.CrossRefGoogle Scholar
  7. 7.
    Abbasov, E.S., Umurzakova, M.A., and Boltoboeva, M.P., Efficiency of solar air heaters, Appl. Sol. Energy, 2016, vol. 52, no. 2, pp. 97–99.CrossRefGoogle Scholar
  8. 8.
    Khairnasov, S.M. and Naumova, A.M., Heat pipes application to solar energy systems, Appl. Sol. Energy, 2016, vol. 52, no. 1, pp. 47–60.CrossRefGoogle Scholar
  9. 9.
    Bopche, S.B. and Tandale, M.S., Experimental investigation on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct, Int. J. Heat Mass Transfer, 2009, vol. 52, pp. 2834–2848.CrossRefGoogle Scholar
  10. 10.
    Gupta, M.K. and Kaushik, S.C., Performance evaluation of solar air heater having expanded metal mesh as artificial goughness on absorber plate, Int. J. Therm. Sci., 2009, no. 48, pp. 1007–1016.CrossRefGoogle Scholar
  11. 11.
    Sahu, M.M. and Bhagoria, J.L., Augmentation of heat transfer coefficient by using 90° broken transverse ribs on absorber plate of solar air heater, Renewable Energy, 2005, vol. 30, pp. 2063–2075.CrossRefGoogle Scholar
  12. 12.
    Bhushan, B. and Singh, R., Nusselt number and friction factor correlations for solar air heater duct having artificially roughened absorber plate, Solar Energy, 2011, vol. 85, pp. 1109–1118.CrossRefGoogle Scholar
  13. 13.
    Samiev, M., Klychev, Sh.I., Bakhramov, S.A., et al., Thermal technical efficiency of two-channer solar air heater, Geliotekhnika, 2008, no. 3, pp. 27–31.Google Scholar
  14. 14.
    Kabeel, A.E. and Mecarik, K., Shape optimization for absorber plates of solar air collectors, Renewable Energy, 1998, vol. 13, pp. 121–131.CrossRefGoogle Scholar
  15. 15.
    Ozgen, F., Esen, M., and Esen, H., Experimental investigation of thermal performance of a double-flow solar air heater having aluminium cans, Renewable Energy, 2009, vol. 34, pp. 2391–2398.CrossRefGoogle Scholar
  16. 16.
    Alam, T., Saini, R.P., and Saini, J.S., Effect of circularity of perforation holes in V-shaped blockages on heat transfer and friction characteristics of rectangular solar air heater duct, Energy Convers. Manage., 2014, vol. 86, pp. 952–963.CrossRefGoogle Scholar
  17. 17.
    Fox, W., Pritchard, P., and McDonald, A., Introduction to Fluid Mechanics, New York: Wiley, 2010, p.754.zbMATHGoogle Scholar
  18. 18.
    Gawande, V.B., Dhoble, A.S., and Zodpe, D.B., Effect of roughness geometries on heat transfer enhancement in solar thermal systems—a review, Renewable Sustainable Energy Rev., 2014, vol. 32, pp. 347–378.CrossRefGoogle Scholar
  19. 19.
    Pashchenko, D.I., Thermochemical recovery of heat contained in flue gases by means of bioethanol conversion, Thermal Eng., 2013, vol. 60, no. 6, pp. 438–443CrossRefGoogle Scholar
  20. 20.
    Nikitin, M.N. and Tsynaeva, A.A., Study of the flow in a channel with dumbbell-shaped dimples, Proc. Eng., 2016, vol. 150, pp. 2340–2344.CrossRefGoogle Scholar
  21. 21.
    Gupta, D., Solanki, S.C., and Saini, J.S., Thermohydraulic performance of solar air heaters with roughened absorber plates, Solar Energy, 1997, vol. 61, pp. 33–42.CrossRefGoogle Scholar

Copyright information

© Allerton Press, Inc. 2018

Authors and Affiliations

  1. 1.Samara State Technical UniversitySamaraRussia

Personalised recommendations