Naproxen membrane electrodes based on different plasticizers and the quaternary ammonium salts (QASs) dimethyldidecylammonium bromide, methyltrioctylammonium chloride, or tetraoctylammonium chloride, were prepared. The following basic parameters were investigated for the optimal electrode: measurement range (10−4 − 10−1 mol L−1), slope of the linear range of the calibration curve (−58.3 mV decade−1), limit of detection (6.0 × 10−5 mol L−1), lifetime (2.5 months), dependence of the electrode potential on pH (5.5 − 9.0), reproducibility of potential (1.2 mV) and selectivity coefficients in relation to selected organic and inorganic anions. The electrode was utilized for determination of naproxen in tablets by the calibration curve method and the standard addition method.
Similar content being viewed by others
References
V. V. Cosofret, R. P. Buck, Crit. Rev. Anal. Chem. 1, 24 (1993)
R. I. Stefan, G. E. Baiulescu, Y. Hassan, Crit. Rev. Anal. Chem. 27, 307 (1997)
Z. Z. Zhang, V. V. Cosofret, Selective Electrode Rev. 12, 35 (1990)
V. V. Cosofret, R. P. Buck, Pharmaceutical Applications of Membrane Sensors (CRC Press, Boca Raton, FL, 1992)
P. Solich, P. E. Macheras, M. A. Koupparis, J. Pharm. Sci. 84, 889 (1995)
The Merck Index (Inc. Whitehouse Station, NY, 1996)
J. K. Podlewski, A. Chwalibowska-Podlewska, Leki Wspólczesnej Terapii (PZWL, Warszawa, 1985)
British Pharmacopoeia, Vol. 1 (The Stationery Office, London, 1999)
The United States Pharmacopeia, XXII (INC., Rockville MD, 1990)
R. Dumkiewicz, K. Sykut, A. Kusak, Chem. Anal. (Warsaw) 37, 35 (1992)
R. Dumkiewicz, C. Wardak, K. Pokrzywa, Chem. Anal. (Warsaw) 44, 857 (1999)
Bunaciu, A. Grasu, H. Y. Aboul-Enein, Anal. Chim. Acta, 311, 193 (1995)
J. Lenik, C. Wardak, B. Marczewska, Acta Poloniae Pharmaceutica, 63, 239 (2006)
R. I. Stefan, H. Y. Aboul-Enein, Anal. Lett. 29, 35 (1996)
H. Hopkala, G. Misztal, Pharmazie 51, 96 (1996)
M.N.M.P. Alcada, J.L.F.C. Lima, M.C.B.S.M. Montenegro, J. Pharm. Biomed. Anal. 10, 757 (1992)
J. Lenik, R. Dumkiewicz, C. Wardak, B. Marczewska, Acta Polonia Pharmaceutica 59, 171 (2002)
G.N. Valsami, P.E. Macheras, Analyst 114, 387 (1989)
A. O. Santini, J. E. Oliveira, H. R. Pezza, L. Pezza, J. Braz. Chem. Soc. 17, 785 (2006)
J. Lenik, B. Marczewska, C. Wardak, Desalination 163, 77 (2004)
V.P.Y. Gadzekpo, G.D. Christian, Anal. Chim. Acta 164, 279 (1984)
Schwake, K. Camman, A. L. Smirnova, S. S. Levitchevm, V. L. Grekovich, Yu. G. Vlasov, Anal. Chim. Acta 19, 393 (1999)
F. Hofmeister, Arch. Exp. Patol. Pharmacol. 24, 247 (1888)
R. Dumkiewicz, J. Lenik, Chem. Anal. (Warsaw) 46, 31 (2001)
E. Lindner, Y. Umezawa, Pure Appl. Chem. 80 (1) 85 (2008)
Clarke’s Isolation and Identification of Drugs, 2nd edition (The Pharmaceutical Press, London, 1986)
Author information
Authors and Affiliations
Corresponding author
About this article
Cite this article
Lenik, J., Wardak, C. & Marczewska, B. Properties of naproxen ion-selective electrodes. cent.eur.j.chem. 6, 513–519 (2008). https://doi.org/10.2478/s11532-008-0075-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2478/s11532-008-0075-7