Abstract
The sensitivity for the chemiluminescent (CL) detection of nucleosides and their derivatives was improved by using clinoptirolite chemically modified with cupric nitrate, Cu-Zeo. Cu-Zeo plays a key role as a solid medium for such so-called material exchangers as ion exchange between copper(II) coated on Cu-Zeo and nucleosides and their derivatives. The properties for material exchange were examined by a batch method in which Cu-Zeo (1.5 g; particle size, 250 mesh) was added into the analyte solution (100 ml). Analytes were indirectly determined by the CL analysis of cupric ions eluted from the Cu-Zeo through the material exchange. For the CL detection of cupric ions, an FIA/CL system using a 1,10-phenanthroline CL was employed. The lower limits of detection for analytes were improved by 42 times for adenosine (1.9 pmol/20 μl) and by 16 times for uridine-5’-diphosphate (5.5 pmol/ 20 μl), compared with those by our previous method.
Similar content being viewed by others
References
M. Ishii and M. Yamada, Bunseki, 1989, 442.
M. Ishii, M. Yamada and S. Suzuki, Bunseki Kagaku, 35, 542 (1986).
M. Ishii, M. Yamada and S. Suzuki, Bunseki Kagaku, 35, 955 (1986).
M. Ishii, N. Okubo, T. Baba, M. Yamada and S. Suzuki, Bunseki Kagaku, 38, 53 (1989).
M. Ishii, M. Yamada and S. Suzuki, Anal. Lett., 19, 1591 (1986); Bunseki Kagaku, 35, 373 (1986).
C. L. Malehorn, T. E. Riehl and W. L. Hinz, Analyst [London], 111, 941 (1986).
M. Yamada and S. Suzuki, Anal. Chim. Acta, 193, 337 (1987).
S. A. Al-Tamrah and A. Townshend, Anal. Chim. Acta, 102, 247 (1987).
M. Ishii and M. Shirai, Bunseki Kagaku, 41, 125 (1992).
M. Ishii and M. Koike, Proceedings of the 40th Annual Meeting of The Japan Society for Analytical Chemistry, Tokyo, November 1991, p. 265.
T. Nakagama, M. Yamada and T. Hobo, Anal. Chim. Acta, 231, 7 (1990).
M. Ishii, Anal. Sci., 7, 703 (1991).
T. Kaneyasu, T. Kamidate and H. Watanabe, Proceedings of the ’91 Hokkaido Winter Seminor of The Japan Society for Analytical Chemistry, Hokkaido, February 1991, p. 23.
T. Fujinaga, Proceedings of the 28th Annual Meeting of The Japan Society for Analytical Chemistry, Fukushima, October 1979, p. 394.
T. Kato, S. J. Berger, J. A. Carter and O. H, Lowry, Anal. Biochem., 53, 86 (1989).
H. Arakawa, M. Maeda, A. Tsuji and T. Takahashi, Chem. Pharm. Bull, 37, 1831 (1989).
H. Nouda and Y. Ohkura, Proceedings of the 39th Annual Meeting of The Japan Society for Analytical Chemistry, Nagoya, October 1990, p. 417.
M. Ishii and T. Ohtaki, Proceedings of the 2nd Annual Meeting of The Japan Society on Adsorption, Tokyo, November 1988, p. 62.
M. Ishii and K. Kaji, Gypsum & Lime, 186, 228 (1983).
M. Ishii, Y. Ohno and T. Hobo, Anal Sci., 7, 873 (1991).
K. Sakurai, “Kagaku no Ryouiki Zoukan No. 79; Kakusan no Sakutai Kagaku (Complex Chemistry of Nucleotides, in Japanese)”, ed. S. Nakahara, pp. 276–295, Nankodou, Tokyo, 1967.
P. J. Worsfold and A. Nabi, Biolumin. Chemilumi., Proc. Int. Biolumi. Chemilumi. Symp., 4th (1986); pp. 543–546 (1987).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ohno, Y., Hobo, T., Tamura, R. et al. Sensitive Chemiluminescent Detection of Nucleosides and Their Derivatives Using the Material Exchange of Chemically Copper(II)-Modified Natural Zeolite. ANAL. SCI. 8, 647–653 (1992). https://doi.org/10.2116/analsci.8.647
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.8.647