A simple method for reconcentration and separation of trace amounts of bismuth(III) in the presence of large amounts of silver(I) was established by filtration through a membrane filter loaded with hydrous lead di ox ide(HLD), which adsorbed 5-10 µ g of bismuth(III). Bismuth(III) was not affected by the presence of 5-10 g of silver(I) at pH 1, because the adsorption of silver(I) on the HLD occurred at a pH above 2. This method is applicable to the determination of bismuth in high purity silver.
Similar content being viewed by others
References
S. Ito, T. Matsuda and T. Nagai, Bunseki Kagaku, 29, 655 (1980).
S. Ito, T. Matsuda and T. Nagai, Talanta, 31, 292 (1984).
H. Kawano, Y. Nakai, T. Matsuda and T. Nagai, Talanta, 33, 191 (1986).
Y. Kouji, T. Matsuda and T. Nagai, Bunseki Kagaku, 36, 356 (1987)
M. Miyazaki, S. ITO and T. Nagai, Bunseki Kagaku, 37, 544 (1988).
K. Umori, T. Matsuda and T. Nagai, Bunseki Kagaku, 39. 207 (1990).
H. Kawano, M. Nakamoto, D. Kuroda and T. Nagai, Nippon Kagaku Kaishi, 1991, 386.
T. Matsuda and T. Nagai, Bunseki Kagaku, 38, 82 (1989).
JIS H 1181(1976).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Matsuda, T., Nagai, T. Preconcentration and Separation of Trace Amounts of Bismuth in High Purity Silver with Hydrous Lead Dioxide. ANAL. SCI. 7 (Suppl 1), 75–78 (1991). https://doi.org/10.2116/analsci.7.Supple_75