Skip to main content
Log in

Effects of Ion Optics on the Sensitivity Factors in Secondary Neutral Mass Spectrometry Measurements

  • Original Paper
  • Published:
Analytical Sciences Aims and scope Submit manuscript

Abstract

The effects of the ion optics of the SNMS (secondary neutral mass spectrometry) INA-3 system on the intensity ratios, from which the relative sensitivity factors can be calculated, have been investigated for several III-V semiconductors: GaAs, GaP, and InP. It was found that the intensity ratios change significantly, depending on the electrode potentials of the ion optics and on the mass difference (ΔM) between the major constituent elements: within 90% regions of optimum electrode voltages and between ΔM=6 and 84 amu, the maximum total relative deviation of relative intensities increases from about 10% to 250%.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. W. Reuter, Tr. Anal. Chem., 8, 203 (1989).

    Article  CAS  Google Scholar 

  2. P. K. Chu, J. C. Hunke and R. J. Blattner, J. Vac. Sci. Technol., A5, 295 (1987).

    Article  CAS  Google Scholar 

  3. R. Jede, H. Peter, G. Dunnebier, O. Ganschow, U. Kaiser and K. Seifert, J. Vac. Sci. Technol, A6, 2271 (1988).

    Article  Google Scholar 

  4. K. H. Muller and H. Oechsner, Mikrochim. Acta [Wien], 1983, Suppl. 10, 51.

    Article  Google Scholar 

  5. H. Oechsner, Topics Current Phys., 37, 63 (1984).

    Article  CAS  Google Scholar 

  6. T. Ishitani, N. Sakudo, H. Tamara and I. Kanomata, Phys. Lett., 68A, 375.

  7. K. F. Müller, K. Seifert and M. Wilmers, J. Vac. Sci. Technol, A3, 1367 (1985).

    Article  Google Scholar 

  8. A. Wucher, J. Vac. Sci. Technol, A6, 2287 (1988).

    Article  Google Scholar 

  9. E. Stumpe, H. Oechsner and H. Schoof, Appl. Phys., 20, 55 (1979).

    Article  CAS  Google Scholar 

  10. H. Oechsner, H. Paulus and P. Bachmann, J. Vac. Sci. Technol., A3, 1403 (1985).

    Article  Google Scholar 

  11. R. Jede, U. Kaiser, H. Peter, O. Ganschow and J. P. Denis, “Secondary Ion Mass Spectroscopy SIMS VI”, “Proc. 6th Int. Conf. Versailles 1987”, ed. A. Benninghoven, A. M. Huber and H. W. Werner, p. 353, Wiley, New York.

  12. H. Oechsner and E. Stumpe, Appl. Phys., 14, 43 (1977).

    Article  CAS  Google Scholar 

  13. A. Wucher, F. Novak and W. Reuter, J. Vac. Sci. Technol., A6, 2265 (1988).

    Article  Google Scholar 

  14. A. Wucher and W. Reuter, J. Vac. Sci. Technol., A6, 2316 (1998).

    Google Scholar 

  15. J. Bartella et al., to be published.

  16. A. Wucher, J. Vac. Sci. Technol, A6, 2293 (1988).

    Article  Google Scholar 

  17. 1NA-3 Ion optics manual, Leybold AG, Cologne, FRG.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kikuta, Y., Jenett, H. Effects of Ion Optics on the Sensitivity Factors in Secondary Neutral Mass Spectrometry Measurements. ANAL. SCI. 7, 757–761 (1991). https://doi.org/10.2116/analsci.7.757

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.7.757

Keywords

Navigation