Abstract
A high-performance liquid chromatographic method was developed for the assay of ofloxacin in serum. The serum samples were filtered through a Molcut II membrane filter after partial deproteinization in order to remove proteins. The filtrate was preseparated on a reversed-phase precolumn and introduced onto a reversed-phase analytical column by applying column-switching techniques. Ofloxacin and nalidixic acid as internal standards were detected by absorbance measurements at 300 nm. Using this system the concentration of ofloxacin could be determined at a limit of the order of 20 ng/ ml, with a linear dynamic range of 80 - 4000 ng/ ml. This procedure was applied to pharmacokinetic studies of healthy volunteers treated with ofloxacin.
Similar content being viewed by others
References
K. Sato, Y. Matsuura, M. Inoue, T. Une, Y. Osada, H. Ogawa and M. Mitsuhashi, Antimicrob. Agents Chemother., 22, 548 (1982).
M. R. Lockley, R. Wise and J. Dent, J. Antimicrob, Chemother., 14, 647 (1984).
A. Le Coguic, R. Bidault, R. Farinotti and A. Dauphin, J. Chromatogr., 434, 320 (1988).
A. Mignot and M. A. Lefebvre, J. Chromatogr., 430, 192 (1988).
Y. Katagiri, K. Naora, N. Ichikawa, M. Hayashibara and K. Iwamoto, J. Chromatogr., 431, 135 (1988).
K. Ochiai, H. Takeuchi, Y. Ogawa, S. Shimada, S. Murase, F. Tomonaga and H. Kubo, Jpn. J. Hosp. Pharm., 14, 323 (1988).
T. Ohkubo and T. Nambara, J. Chromatogr., 527, 441 (1990).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ohkubo, T., Kudo, M. & Sugawara, K. High-Performance Liquid Chromatographic Determination of Ofloxacin in Serum. ANAL. SCI. 7, 741–743 (1991). https://doi.org/10.2116/analsci.7.741
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.7.741