Rapid On-Site Air Sampling with a Needle Extraction Device for Evaluating the Indoor Air Environment in School Facilities

  • Published:
Analytical Sciences Aims and scope Submit manuscript

Abstract

A rapid on-site air sampling technique was developed with a miniaturized needle-type sample preparation device for a systematic evaluation of the indoor air environments in school facilities. With the in-needle extraction device packed with a polymer particle of divinylbenzene and activated carbon particles, various types of volatile organic compounds (VOCs) were successfully extracted. For evaluating the indoor air qualities in school facilities, air samples in renovated rooms using organic solvent as a thinner of the paint were analyzed along with measurements of several VOCs in indoor air samples taken in newly built primary schools mainly using low-VOCs materials. After periodical renovation/maintenance, the time-variation profile of typical VOCs found in the school facilities has also been monitored. From the results, it could be observed that the VOCs in most of the rooms in these primary schools were at a quite low level; however, a relatively higher concentration of VOCs was found in some specially designed rooms, such as music rooms. In addition, some non-regulated compounds, including benzyl alcohol and branched alkanes, were detected in these primary schools. The results showed a good applicability of the needle device to indoor air analysis in schools, suggesting a wide range of future employment of the needle device, especially for indoor air analysis in other types of facilities and rooms including hospitals and hotels.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. A. Clausen, K. Wilkins, and P. Wolko, J. Chromatogr., A, 1998, 814, 161.

    Article  CAS  Google Scholar 

  2. J. Jansz, in “Sick Building Syndrome”, ed. S. A. Abdul-Wahab, 2011, Chap. 1, Springer-Verlag, Berlin Heidelberg.

  3. S. N. Sinha, P. K. Kulkarni, N. M. Desai, S. H. Shah, G. M. Patel, M. M. Mansuri, D. J. Parikh, and H. N. Saiyed, J. Chromatogr., A, 2005, 1065, 315.

    Article  CAS  PubMed  Google Scholar 

  4. The Japan Ministry of Health, Labour and Welfare, Notice No. 261, 2003.

  5. The Japan Ministry of Health, Labour and Welfare, Committee on Sick House Syndrome, Indoor Air Pollution Progress Report No. 1, 2000.

  6. R. E. Clement and P. W. Yang, Anal. Chem., 2001, 73, 2761.

    Article  CAS  PubMed  Google Scholar 

  7. M. R. Ras, F. Borrull, and R. M. Marcé, Trends Anal. Chem., 2009, 28, 347.

    Article  CAS  Google Scholar 

  8. G. Bertoni, C. Ciuchini, A. Pasini, and R. Tappa, J. Environ. Monit., 2002, 4, 903.

    Article  CAS  PubMed  Google Scholar 

  9. P. N. Pegas, C. A. Alves, M. G. Evtyugina, T. Nunes, M. Cerqueira, M. Franchi, C. A. Pio, S. M. Almeida, and M. C. Freitas, Environ. Geochem. Health, 2011, 33, 455.

    Article  CAS  PubMed  Google Scholar 

  10. M. Inoue, Y. Saito, I. Ueta, T. Miura, H. Ohkita, K. Fujimura, and K. Jinno, Anal. Sci., 2010, 26, 687.

    Article  CAS  PubMed  Google Scholar 

  11. I. Ueta and Y. Saito, Bunseki Kagaku, 2011, 60, 833.

    Article  CAS  Google Scholar 

  12. Y. Saito, I. Ueta, M. Ogawa, A. Abe, K. Yogo, S. Shirai, and K. Jinno, Anal. Bioanal. Chem., 2009, 393, 861.

    Article  CAS  PubMed  Google Scholar 

  13. I. Ueta, K. Takahashi, and Y. Saito, Anal. Sci., 2012, 28, 953.

    Article  CAS  PubMed  Google Scholar 

  14. Y. Saito, I. Ueta, K. Kotera, M. Ogawa, H. Wada, and K. Jinno, J. Chromatogr., A, 2006, 1106, 190.

    Article  CAS  PubMed  Google Scholar 

  15. I. Ueta, Y. Saito, N. B. A. Ghani, M. Ogawa, K. Yogo, A. Abe, S. Shirai, and K. Jinno, J. Chromatogr., A, 2009, 1216, 2848.

    Article  CAS  PubMed  Google Scholar 

  16. Y. Saito, I. Ueta, M. Ogawa, and K. Jinno, Anal. Bioanal. Chem., 2006, 386, 725.

    Article  CAS  PubMed  Google Scholar 

  17. Y. Saito, I, Ueta, M. Ogawa, M. Hayashida, and K. Jinno, J. Pharm. Biomed. Anal., 2007, 44, 1.

    Article  CAS  PubMed  Google Scholar 

  18. I. Ueta, Y. Saito, K. Teraoka, T. Miura, and K. Jinno, Anal. Sci., 2010, 26, 569.

    Article  CAS  PubMed  Google Scholar 

  19. I. Ueta, Y. Saito, K. Teraoka, H. Matsuura, K. Fujimura, and K. Jinno, Anal. Sci., 2010, 26, 1127.

    Article  CAS  PubMed  Google Scholar 

  20. I. Ueta, Y. Saito, M. Hosoe, M. Okamoto, H. Ohkita, S. Shirai, H. Tamura, and K. Jinno, J. Chromatogr., B, 2009, 877, 2551.

    Article  CAS  Google Scholar 

  21. I. Ueta, A. Mizuguchi, K. Fujimura, S. Kawakubo, and Y. Saito, Anal. Chim. Acta, 2012, 746, 77.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yoshihiro Saito.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Inoue, M., Mizuguchi, A., Ueta, I. et al. Rapid On-Site Air Sampling with a Needle Extraction Device for Evaluating the Indoor Air Environment in School Facilities. ANAL. SCI. 29, 519–525 (2013). https://doi.org/10.2116/analsci.29.519

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.29.519

Navigation