Abstract
We improved the detection sensitivity of neutral and amino monosaccharides labeled with 2-aminoacridone by a factor of 19.6 - 48.7 and 44.4 - 65.9, respectively, with no deterioration in separation resolution, using a pH discontinuous solution system instead of the conventional solution system. The pH discontinuous solution system is simple, using only a borate solution at pH 6.0 as a sample solution and a Tris-borate solution at pH 9.3 as a separation solution, enabling an enhancement of the sensitivity by monosaccharide stacking. This technique is fully compatible with conventional microchip electrophoresis, thereby allowing us to develop efficient tools for highly sensitive and resolved detection of monosaccharides.
Similar content being viewed by others
References
A. Varki, Glycobiology, 1993, 3, 97.
S. Hoffstetter-Kuhn, A. Paulus, E. Gassmann, and H. M. Widmer, Anal. Chem., 1991, 63, 1541.
A. Manz, D. J. Harrison, E. M. J. Verpoorte, J. C. Fettinger, A. Paulus, H. Ludi, and H. M. Widmer, J. Chromatogr., 1992, 593, 253.
A. T. Wooley and R. A. Mathies, Proc. Natl. Acad. Sci. U. S. A., 1994, 91, 11348.
S. C. Jacobson, R. Hergenroder, L. B. Koutny, R. J. Warmack, and J. M. Ramsey, Anal. Chem., 1994, 66, 1107.
M. Ueda, Y. Kiba, H. Abe, A. Arai, H. Nakanishi, and Y. Baba, Electrophoresis, 2000, 21, 176.
I. Rodriguez, L. J. Jin, and S. F. Li, Electrophoresis, 2000, 21, 211.
H. Nagata, M. Tabuchi, K. Hirano, and Y Baba, Electrophoresis, 2005, 26, 2247.
H. Nagata, M. Tabuchi, K. Hirano, and Y. Baba, Electrophoresis, 2005, 26, 2687.
S. Suzuki, N. Shimotsu, S. Honda, A. Arai, and H. Nakanishi, Electrophoresis, 2001, 22, 4023.
E. Maeda, K. Hirano, Y Baba, H. Nagata, and M. Tabuchi, Electrophoresis, 2006, 27, 2002.
E. Maeda, M. Kataoka, M. Hino, K. Kajimoto, N. Kaji, M. Tokeshi, J. Kido, Y Shinohara, and Y Baba, Electrophoresis, 2007, 28, 2927.
E. Maeda, M. Kataoka, S. Yatsushiro, K. Kajimoto, M. Hino, N. Kaji, M. Tokeshi, M. Bando, J. Kido, M. Ishikawa, Y. Shinohara, and Y Baba, Electrophoresis, 2008, 29, 1902.
Z. El Rassi, Electrophoresis, 1990, 20, 3134.
U. K. Laemmli, Nature, 1970, 227, 680.
H. Nagata, M. Ishikawa, Y. Yoshida, Y Tanaka, and K. Hirano, Electrophoresis, 2008, 29, 3744.
F. Dang, L. Zhang, H. Hagiwara, Y Mishina, and Y Baba, Electrophoresis, 2003, 24, 714.
Y Baba, N. Ishimura, K. Samata, and M. Tsuhako, J. Chromatogr, A, 1993, 653, 329.
M. Van Duin, J. A. Peters, A. P. G. Kieboom, and H. Van Bekkum, Tetrahedron, 1984, 40, 2901.
M. Van Duin, J. A. Peters, A. P. G. Kieboom, and H. Van Bekkum, Tetrahedron, 1985, 41, 3411.
Author information
Authors and Affiliations
Electronic supplementary material
Rights and permissions
About this article
Cite this article
Nagata, H., Itoh, T., Baba, Y. et al. Highly Sensitive Detection of Monosaccharides on Microchip Electrophoresis Using pH Discontinuous Solution System. ANAL. SCI. 26, 731–736 (2010). https://doi.org/10.2116/analsci.26.731
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.26.731