Abstract
An analytical method has been described for the determination of mercury using a carbon paste electrode. Conditions for the preparation of the carbon paste electrode were optimized for low background current in order to use it for the determination of ultra trace levels of mercury. The carbon paste electrode was found to be a good electrode material for the determination of mercury. The optimized pH for the determination was in the range of 2.5 to 3.5. The three sigma detection limit of mercury was obtained as 0.095 μg L-1. Method has been modified for determination of mercury in cobalt sulfate samples.
Similar content being viewed by others
References
C. Sarzanini and E. Mentaste, Ann. Chim. Rome, 1991, 343, 81.
R. E. Clement, G. A. Eiceman, and Koester, Anal. Chem., 1995, 221R, 67.
N. Sayama, Y. Yoshida, K. Mori, H. Fukazawa, H. Hori, M. Nakazato, J. I. Tani, Y Nakagawa, and S. Ito, Endocr. J., 1998, 767, 45.
D. Gibicar, M. Logar, N. Horvat, A. Marn-Pernat, R. Ponikvar, and M. Horvat, Anal. Bioanal. Chem., 2007, 329, 388.
C. M. Watson, D. J. Dwyer, J. C. Andle, A. E. Bruce, and M. R. M. Bruce, Anal. Chem., 1999, 3181, 71.
O. Ordeig, C. E. Banks, J. del Campo, F. X. Munox, and R. G. Compton, Electroanalysis, 2006, 573, 6.
S. Berchmans, S. Arivukkodi, and V. Yegnaraman, Electrochem. Commun., 2000, 226, 2.
S. S. Rio and J. F. Tyson, Talanta, 2007, 1696, 71.
F. Ubillus, A. Algeria, R. Barbera, R. Farre, and M. J. Lagarda, Food Chem., 2000, 529, 71.
M. Karolczuk, Fresenius’ J. Anal. Chem., 1997, 389, 357.
B. K. Jena and C. R. Raj, Anal. Chem., 2008, 4836, 80.
X. Xue, F. Wang, and X. Liu, J. Am. Chem. Soc., 2008, 3244, 130.
Z. Zhu, Y. Su, J. Li, D. Li, J. Zhang, S. Song, Y. Zhao, G. Li, and C. Fan, Anal. Chem., 2009, 7660, 81.
I. K. Tonle, E. Ngameni, and A. Walcarius, Sens. Actuators, B, 2005, 195, 110.
E. Shams and R. Torabi, Sens. Actuators, B, 2006, 86, 117.
N. L. Filho, D. R. do Carmo, F. Gessner, and A. H. Rosa, Anal. Sci., 2005, 21, 1309.
N. L. Dias Filho, D. R. do Carmo, L. Caetano, and A. H. Rosa, Anal. Sci., 2005, 21, 1359.
A. Manivannan, M. S. Seehra, D. A. Tryk, and A. Fujishima, Anal. Lett., 2002, 35, 355.
H. Yi, Anal. Bioanal. Chem., 2003, 377(4), 770.
E. R. E. Mojica and F. E. Merca, J. Appl. Sci., 2005, 5(8), 1461.
A. Mandil, L. Idrissi, and A. Amine, Microchim. Acta, 2010, 170, 299.
F. Wang, J. Liu, Y. J. Wu, Y. M. Gao, and X. F. Huang, J. Chin. Chem. Soc., 2009, 56, 778.
M. C. Rizea, A. F. Dane, and S. Kalinowski, Rev. Chim., 2007, 58(3), 266.
F. Tao, Y. Q. Zhao, G.-Q. Zhang, and H.-L. Li, Electrochem. Commun., 2007, 9, 1282.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Sahoo, S., Satpati, A.K. & Reddy, A.V.R. Voltammetric Determination of Trace Levels of Hg in Ayurvedic Medicine and in Cobalt-Containing Samples Using a Carbon Paste Electrode. ANAL. SCI. 26, 1309–1312 (2010). https://doi.org/10.2116/analsci.26.1309
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.26.1309