Abstract
In this study, a fast, simple and highly sensitive method that employs liquid phase microextraction (LPME)-GC/MS was developed to analyze trace benzophenones (BPs) in river-water samples. The tip of a 10-µl microsyringe filled with toluene (3 µl) was inserted into 2 µl of a river-water sample, and fixed at 5 mm below the water surface of the sample. A toluene droplet was made on the tip of the syringe, and extraction was conducted while agitating at 500 rpm for 15 min. After extraction, 2.0 µl of the extract was put into the syringe again, and directly introduced to GC/MS. The limits of detection (S/N = 3) and quantification (S/N >10) of BPs were 10 and 50 pg ml−1, respectively. The results of a recovery test ranged over 93.3–101.1% (RSD, less than 10%; n = 6). The results of BPs determinations in the river-water samples showed that BPs (ND-68.9 pg ml−1) were detected.
Similar content being viewed by others
References
M. M. Rieger, Cosmetics and Toiletries, 1997, 112, 65.
F. J. Moloney, S. Collins, and G. M. Murphy, Am. J. Clin. Dermatol., 2002, 3, 185.
J. L. Bourrain, P. Amblard, and J. C. Beani, Contact Dermatitis, 2003, 48, 45.
M. Schlumpf, B. Cotton, M. Conscience, V. Haller, B. Steinmann, and W. Lichtensteiger, Environ. Health Perspect., 2001, 109, 239.
Y. Nakagawa and T. Suzuki, Chem.-Biol. Interact., 2002, 156, 27.
S. Takatori, Y. Kitagawa, H. Oda, G. Miwa, J. Nishikawa, T. Nishihara, H. Nakagawa, and S. Hori, J. Health Sci., 2003, 49, 91.
X. Ye, Z. Kuklenyik, L. L. Needham, and A. M. Calafat, Anal. Chem., 2005, 77, 5407.
S.-P. Wang and W.-T. Lee, J. Chromatogr., A, 2003, 987, 269.
T. Felix, B. J. Hall, and J. S. Brodbelt, Anal. Chim. Acta, 1998, 371, 195.
L. H. Wang, Chromatographia, 1999, 50, 565.
H.-K. Jeon, Y. Chung, and J.-C. Ryu, J. Chromatogr., A, 2006, 1131, 192.
A. L. Gregory and E. P. Mark, Environ. Sci. Technol., 2006, 40, 687.
X. Ye, Z. Kuklenyik, L. L. Needham, and A. M. Calafat, Anal. Bioanal. Chem., 2005, 383, 638.
Y. He and H. K. Lee, Anal. Chem., 1997, 69, 4634.
Y. Wang, Y. C. Kwok, Y. He, and H. K. Lee, Anal. Chem., 1998, 70, 4610.
M. Kawaguchi, R. Ito, N. Endo, N. Okanouchi, N. Sakui, K. Saito, and H. Nakazawa, J. Chromatogr., A, 2006, 1110, 1.
E. Psillakis and N. Kalogerakis, Trends Anal. Chem., 2003, 22, 565.
L. Zhao and H. K. Lee, J. Chromatogr., A, 2001, 919, 381.
C. Basheer, H. K. Lee, and J. P. Obbard, J. Chromatogr., A, 2002, 968, 191.
S. Pedersen-Bjergaard and K. E. Rasmussen, Electrophoresis, 2000, 21, 579.
H. G. Ugland, M. Krogh, and K. E. Rasmussen, J. Chromatogr., B, 2000, 749, 85.
M. Saraji, J. Chromatogr., A, 2005, 1062, 15.
E. González- Peñas, C. Leache, M. Viscarret, A. Pérez De Obanos, C. Araguás, and A. López De Cerain, J. Chromatogr., A, 2004, 1025, 163.
M. Kawaguchi, R. Ito, N. Endo, N. Sakui, N. Okanouchi, K. Saito, N. Sato, T. Shiozaki, and H. Nakazawa, Anal. Chim. Acta, 2006, 557, 272.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Okanouchi, N., Honda, H., Ito, R. et al. Determination of Benzophenones in River-water Samples Using Drop-based Liquid Phase Microextraction Coupled with Gas Chromatography/Mass Spectrometry. ANAL. SCI. 24, 627–630 (2008). https://doi.org/10.2116/analsci.24.627
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.24.627