Abstract
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N′-ethylene-bis(4-methyl-salicylidineiminato)nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a good Nernstian slope of −58.9 ± 0.7 mV decade−1, over a wide pH range of 3.5–8.5 and a linear range of 1.0 × 10−6–1.0 × 10−1 M for thiocyanate. The detection limit of electrode was 3.1 × 10−7 M SCN–. The selectivity coefficients determined by a fixed interference method (FIM) indicate that a good discriminating ability towards the SCN− ion compared to other anions. The proposed sensor had a fast response time of about 5–15 s and could be used for at least 3 months without any considerable divergence in the potential. It was applied as an indicator electrode in the titration of thiocyanate with Ag+ and in the potentiometric determination of thiocyanate in saliva and urine samples.
Similar content being viewed by others
References
W. J. Williams, “Handbook of Anion Determination”, 1984, Butterworths, London, 228.
W. C. Butts, M. Kuehneman, and G. M. Widdowson, Clin. Chem., 1974, 20, 1344.
A. B. Bedtsen and E. H. Hansen, Analyst, 1991, 116, 647.
R. D. Montgomery, “Toxic Constituents of Plant Foodstuffs”, ed. I. E. Liener, 1969, Academic Press, New York, 143.
E. Bakker, P. Bühlmann, and E. Pretsch, Chem. Rev., 1997, 97, 3083.
M. E. Meyerhoff, Clin. Chem., 1990, 36, 1567.
D. Ammann, “Ion-Selective Microelectrodes”, 1986, Springer, Berlin.
Y. Umezawa, “CRC Handbook of Ion-Selective Electrodes: Selectivity Coefficients”, 1990, CRC Press, Boca Raton, Ann Arbor, Boston.
P. Schulthess, D. Ammann, B. Krautler, C. Caderas, R. Stepanek, and W. Simon, Anal. Chem., 1985, 57, 1397.
R. Stepanek, B. Kraultler, P. Schulthess, B. Lindemann, D. Ammann, and W. Simon, Anal. Chim. Acta, 1986, 182, 83.
N. A. Chaniotaksi, A. M. Chasser, and M. E. Meyerhoff, Anal. Chem., 1998, 60, 185.
E. Bakker, E. Malinowska, R. D. Schiller, and M. E. Meyerhoff, Talanta, 1994, 41, 881.
M. K. Amini, S. Shahrokhian, and S. Tangestaninejad, Anal. Chem., 1999, 71, 2502.
M. E. Meyerhoff, D. M. Pranitis, H. S. Yim, N. A. Chaniotakis, and S. B. Park, Anal. Chim. Acta, 1989, 217, 123.
R. Yuan, Y. Chai, D. Liu, D. Gao, J. Li, and R. Yu, Anal. Chem., 1993, 65, 2572.
J. Li, X. Wu, R. Yuan, H. Lin, and R. Yu, Analyst, 1994, 119, 1363.
T. Nakamura, C. Hayashi, and T. Ogawara, Bull. Chem. Soc. Jpn., 1996, 69, 1555.
M. K. Amini, S. Shahrokhian, and S. Tangestaninejad, Anal. Chim. Acta, 1999, 402, 137.
I. H. A. Badr, M. E. Meyerhoff, and S. S. M. Hassan, Anal. Chem., 1995, 67, 754.
J. Bricker, S. Daunert, L. G. Bachas, and M. Valiente, Anal. Chem., 1991, 63, 1585.
M. Mazloum, A. A. Ensafi, M. Salavati, and S. Mirhoseini, Anal. Chim. Acta, 2002, 462, 25.
E. S. William, J. Org. Chem., 1972, 37, 3972.
M. M. Ardekany, A. A. Ensafi, H. Naeimi, A. Dastanpour, and A. Shamelli, Sens. Actuators, B, 2003, 96, 441.
H. Sharghi and H. Naeimi, Iran. J. Chem. Chem. Eng., 1999, 18, 72.
M. Mazloum, M. Salavati, and A. Sadeghi, New. J. Chem., 2004, 28, 595.
S. Kamata, A. Bhal, Y. Fukunaga, and A. Murata, Anal. Chem., 1988, 60, 2464.
M. Shamsipur, M. Yousefi, M. Hosseini, M. R. Ganjali, T. Poursaberi, and M. Faal-Rastgar, Sens. Actuators, B, 2002, 82, 105.
D. Ammann, E. Pretsch, W. Simon, E. Lindner, A. Bezegh, and E. Pungor, Anal. Chim. Acta, 1985, 171, 119.
P. M. Gehring, W. E. Morf, M. Welti, E. Pretsch, and W. Simon, Helv. Chim. Acta, 1990, 73, 203.
R. P. Buck, Anal. Chem., 1972, 44, 270R.
D. Wegmann, H. Weiss, D. Ammann, W. E. Morf, E. Pretsch, K. Sagahara, and W. Simon, Mikrochim. Acta, 1984, III(1–2), 1.
E. Lindner, K. Toth, and E. Pungor, “Dynamic Characteristics of Ion-Selective Electrodes”, 1988, CRC Press, Boca Raton.
E. Bakker, M. Lerchi, T. Rosatzin, B. Rusterholz, and W. Simon, Anal. Chim. Acta, 1993, 278, 211.
S. Daunert, S. Wallace, A. Florido, and L. G. Bachas, Anal. Chem., 1991, 63, 1676.
M. K. Amini, A. Rafi, M. Ghaedi, H. Habibi, and M. M. Zohory, Microchem. J., 2003, 75, 143.
M. R. Ganjali, M. Yousefi, M. Javanbakht, T. Poursaberi, M. S. Niasari, L. H. Babaei, E. Latifi, and M. Shamsipur, Anal. Sci., 2002, 18, 887.
S. S. M. Hassan, M. H. A. Ghalia, A. E. Amr, and A. H. K. Mohamed, Anal. Chim. Acta, 2003, 482, 9.
S. Amemiya, P. Buhlmann, Y. Umezawa, R. C. Jagessar, and D. H. Burns, Anal. Chem., 1999, 71, 1049.
T. G. Whiston and G. W. Cherry, Analyst, 1962, 87, 819.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ardakani, M.M., Jamshidpour, M., Naeimi, H. et al. Thiocyanate Ion-selective PVC Membrane Electrode Based on N,N′-Ethylene-bis(4-methylsalicylidineiminato)nickel(II). ANAL. SCI. 22, 1221–1226 (2006). https://doi.org/10.2116/analsci.22.1221
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.22.1221