The present study was aimed at developing a portable miniaturized FIA system with a two-electrode based amperometric detector for on-site monitoring of residual chlorine in environmental samples. The electrode potential control and current data collection were conducted with a home-designed potentiostat with a size of 150 × 100 × 40 mm and the weight of 350 g. It was confirmed that the amperometric response increased in proportion to the chlorine concentration up to 5 µg/ml, and the detection limit for chlorine was 0.05 µg/ml. Besides a drastic reduction in the size of the analytical system, such miniaturization achieved the advantages of increased speed, minimal mobile-phase consumption, and high sensitivity. The proposed method was successfully applied to the determination of residual chlorine in samples of pool water and tap water. The results were well agreed with those obtained by the N, N-diethyl-p-phenylenediamine (DPD) photometric method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. A. T. Palin, J. Inst. Water Eng., 1967, 21, 537.

    CAS  Google Scholar 

  2. A. van den Berg, M. Koudelka-Hep, B. H. van der Schoot, and N. F. de Rooij, Anal. Chim. Acta, 1992, 269, 75.

    Article  Google Scholar 

  3. A. N. Tsaousis and C. O. Huber, Anal. Chim. Acta, 1985, 178, 319.

    Article  CAS  Google Scholar 

  4. A. Okumura, A. Hirabayashi, Y. Sasaki, and R. Miyake, Anal. Sci., 2001, 17, 1113.

    Article  CAS  Google Scholar 

  5. H. Iketake and A. Yamada, Bunseki Kagaku, 1999, 48, 1123.

    Article  CAS  Google Scholar 

  6. K. Sato, J. Jin, T. Takeuchi, T. Miwa, Y. Takekoshi, S. Kanno, and S. Kawase, Analyst, 2000, 125, 1041.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jiye Jin.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jin, J., Suzuki, Y., Ishikawa, N. et al. A Miniaturized FIA System for the Determination of Residual Chlorine in Environmental Water Samples. ANAL. SCI. 20, 205–207 (2004). https://doi.org/10.2116/analsci.20.205

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.20.205

Navigation