Abstract
A simple method for the selective determination of ammonious nitrogen and cyanide by means of triangle-programmed coulometric titration in a flow through system is described. Ammonia and hydrogen cyanide are transferred across a gas permeable membrane. After absorbtion in a suitable acceptor stream ammonium and cyonide ions are titrated with electrolytically generated OBr- and I2 respectively. The titration curves are followed continuously with a biamperometric flow through detector as a function of time. Linear concentration dependence was found in the ranges of 100 ώg l-1 -50 mg l-1 NH3 and 100 ώg l -1 -40 mg l-1 CIST (r2≥0.999). The standard deviations at 135 ώg l-1 NH3 and at 120 ώg l-1 CN- are 3.1 and 2.8%, respectively.
Similar content being viewed by others
References
T. Röhm, H. C. Nipper and W. C. Purdy, Anal. Chem., 44, 869 (1972).
T. Rohm and W. C. Purdy, Anal. Chim. Acta, 72, 177 (1977).
R. A. Gibbs and R. J. Palma Jr., Anal. Lett., 7, 167 (1974).
J. Mocak, D. I. Bustinand M. Ziakova, Chem. Zvesti, 26, 126 (1972).
G. M. Arcand and E. H. Swift, Anal. Chem., 28, 440 (1956).
G. D. Christian, E. C. Knoblock and W. C. Purdy, Anal. Chem., 35, 2217 (1963).
A. F. Krivis, G. R. Supp and E. S. Gazda, Anal Chem., 35, 2216 (1963).
G. Nagy, K. Tóth and E. Pungor, Anal. Chem., 47, 1460 (1975).
G. Nagy, Zs. Fehér, K. Tóth and E. Pungor, Anal. Chim. Acta, 91, 87 (1977).
G. Nagy, Zs. Fehér, K. Tóth and E. Pungor, Anal. Chim. Acta, 100, 181 (1978).
D. Elter, Diplomamunka, Budapesti Müszaki Egyetem, Budapest (1981).
Unpublished results.
B. Pihlar and L. Kosta, Anal Chim. Acta, 114, 275 (1980).
W. Werner and G. Tölg, Fresenius’ Z. Anal. Chem., 276, 103 (1975).
E. J. Conway, “Microdiffusion Analysis and Volumetric Error”, 4th Ed, London (1957).
E. A. G. Zagatto, B. F. Reis, H. Bergamin F° and F. J. Krug, Anal. Chim. Acta., 109, 45 (1979).
M. E. Meyerhoff and Y. M. Fraticelli, Anal. Lett., 14B, 415 (1981).
W. E. van der Linden, Anal. Chim. Acta, 151, 359 (1983).
M. van Son, R. C. Schothorst and G. Den Boef, Anal. Chim. Acta, 153, 271 (1983).
T. Aoki, S. Uemura and M. Munemori, Bunseki Kagaku, 33, 505 (1984).
C. Okumoto, M. Nagashima, S. Mizoiri, M. Kazama, K. Akiyama; Eisei Kagaku, 30, 7 (1984).
R. A. Durst, Anal. Lett., 10, 961 (1977).
in preparation.
B. Pihlar, L. Kosta and B. Hristovski, Talanta, 26, 805 (1979).
G. Nagy, Zs. Fehér, K. Tóth and E. Pungor, Hung. Sci. Instr., 46, (1979).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Spohn, U., Nagy, G. & Pungor, E. Gas Diffusion Membrane Separation in Triangle-Programmed Coulometric Titrations. ANAL. SCI. 2, 431–437 (1986). https://doi.org/10.2116/analsci.2.431
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.2.431