Supercritical fluid chromatograph (SFC) with a fused silica separation column (0.5 mm I.D.×70 cm) packed with ODS-Q3 (30-50 μm) was directly coupled with a quadrupole mass spectrometer (MS) through a vacuum nebulizing interface originally developed for the combination of high performance liquid chromathograph (HPIC) with MS. Mixtures of hexane and ethanol were used as the mobile phase for SFC at a flow rate of 40 μl/min (50 kg/cm2). The column temperatures were maintained above the critical ones of the mobile phase between 260 and 280°C. Introduction of line filters to remove possible small particles in the SFC effluent and the subtle control of the optimum flow and/or the pressure for the SFC column enabled fairly long term stable operation for this SFC-MS system. Thus developed new system was successfully applied to the analysis of various samples such as styrene oligomers, phthalates, triglycerides, and polyethylene glycol derivatives.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. L. G. Randall and A. L. Wahrhaftig, Anal. Chem., 50, 1703 (1978).

    Article  CAS  Google Scholar 

  2. R. D. Smith, J. C. Fjeldsted and M. L. Lee, J. Chromatogr., 247, 231 (1982).

    Article  CAS  Google Scholar 

  3. R. D. Smith and H. R. Udseth, Anal Chem., 55, 2266 (1983).

    Article  CAS  Google Scholar 

  4. B. W. Wright, H. R. Udsth, R. D. Smith and R. N. Hazlett, J. Chromatogr., 314, 253 (1984).

    Article  CAS  Google Scholar 

  5. Y. Hirata and F. Nakata, J. Chromatogr., 295, 315 (1984).

    Article  CAS  Google Scholar 

  6. Y. Hirata, J. Chromatogr., 315, 31 (1984).

    Article  CAS  Google Scholar 

  7. Y. Hirata, J. Chromatogr., 315, 39 (1984).

    Article  CAS  Google Scholar 

  8. K. Matsumoto and S. Tsuge, Fresenius’ Z. Anal. Chem., in press.

  9. H. Yoshida, K. Matsumoto, K. Itoh, S. Tsuge, Y. Hirata, K. Mochizuki, N. Kokubun, Y. Yoshida, Fresenius’ Z. Anal Chem., 311, 674 (1982).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Matsumoto, K., Tsuge, S. & Hirata, Y. Development of Directly Coupled Supercritical Fluid Chromatography-Mass Spectrometry with Self-Spouting and Vacuum Nebulizing Assisted Interface. ANAL. SCI. 2, 3–7 (1986). https://doi.org/10.2116/analsci.2.3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.2116/analsci.2.3

Keywords

Navigation