Abstract
A porous cellulose tape impregnated with a coloring solution that includes hydroxylamine sulfate, Methyl Yellow (pH indicator; pH 2.9-4,0, red—yellow), glycerin and methanol has been developed to provide a highly sensitive means of detecting formaldehyde gas. Formaldehyde reacts with hydroxylamine sulfate to produce sulfuric acid. When a sample including formaldehyde was passed through the tape, the color of the tape changed from yellow to red. The degree of color change was proportional to the concentration of formaldehyde at a constant sampling time and flow rate. The degree of color change could be recorded by measuring the intensity of reflecting light (555 nm). No interference was observed from carbon monoxide (100 ppm), nitrogen monoxide (50 ppm), nitrogen dioxide (105 ppm), carbon dioxide (4,9%), hydrogen (100%), hydrogen sulfide (32 ppm), or hydrogen fluoride (6 ppm). The response of acetaldehyde and propionaldehyde were one fortieth and three-hundredths of that of formaldehyde, respectively, Reproducibility tests showed that the relative standard deviation of relative intensity (n=10) was 3.4% for 4 ppm formaldehyde. The detection limit was 0.1 ppm for formaldehyde at a sampling time of 5 min and a flow rate of 400 ml/min.
Similar content being viewed by others
References
V. K. Elbert, D. T. Glenn, D. Carl, J. L. William and R. A. Gerald, Am. Ind Hyg. Assoc. J., 43, 786 (1982).
A. P. Altshuller, I. R. Cohen, M. LMeyer and A. F. Wartburg, AnaL Chim. Acta, 25, 101 (1961).
ACGIH: Threshold Limit Values for Chemical Substances and Biological Exposure Indices for 1989-90 (1989).
S. B. Robert, T. S. Leslie, J. E. Larry, K. Renate, F. Henry and B. Leo, Am. Ind Hyg. Assoc. J., 45, 778 (1984).
F. Feigl, “Spot Tests in Organic Analysis”, p. 349, Elsevier Publ. Co., New York, 1954.
S. W. Beck and T. H. Stock, Am. Ind. Hyg. Assoc. J., 51, 14 (1990).
S. Eugene and R. H. Thomas, Anal. Chem., 32, 1434 (1960).
A. C. Rayner and C. W. Jephcott, AnaL Chem., 33, 627 (1961).
P. A. Aubrey, L. M. David and F. S. Stanley, Anal. Chem., 33, 621 (1961).
R. W. Brandon, Proceedings of the International Meeting on Chemical Sensors, Fukuoka, September 1983, p. 726.
N. O. Korolkoff, SoMState TechnoL, 32, 49 (1989).
D. F. Natusch, J. R. Sewell and R. L. Tanner, Anal. Chem., 46, 410 (1974).
N. Nakano, A. Yamamoto, Y. Kobayashi and K. Nagashima, Bunseki Kagaku, 42, 537 (1993).
N. Nakano, A. Yamamoto, Y. Kobayashi and K. Nagashima, Analyst [London], 118, 1543 (1993).
N. Nakano, A. Yamamoto, Y. Kobayashi and K. Nagashima, Bunseki Kagaku, 43, 139 (1994).
C. W. Lee, Y. S. Fung and K. W. Fung, Analyst [London], 107, 30 (1982).
A. P. Altshuller and I. R. Cohen, AnaL Chem., 32, 802 (1960).
“Calibration Standard Notebook” Analytical Instrument Development Inc., Avondale, 1979.
F. T. Weiss, “Determination of Organic Compounds: Methods and Procedures”, p. 84, John Wiley & Sons Inc., New York, 1970.
K. Tanabe, “Solid Acids and Bases”, p. 6, Kodansha, Tokyo, 1970.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Nakano, N., Ishikawa, M., Kobayashi, Y. et al. Development of a Monitoring Tape for Formaldehyde Using Hydroxylamine Sulfate and Methyl Yellow. ANAL. SCI. 10, 641–645 (1994). https://doi.org/10.2116/analsci.10.641
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.2116/analsci.10.641