Abstract

Considering the increasing use of information technology with established standards, such as TCP/IP and XML in modern industrial automation, we present a high cost performance solution with FPGA (field programmable gate array) implementation of a novel reliable real-time data transfer system based on EPA (Ethernet for plant automation) protocol and IEEE 1588 standard. This combination can provide more predictable and real-time communication between automation equipments and precise synchronization between devices. The designed EPA system has been verified on Xilinx Spartan3 XC3S1500 and it consumed 75% of the total slices. The experimental results show that the novel industrial control system achieves high synchronization precision and provides a 1.59-μs standard deviation between the master device and the slave ones. Such a real-time data transfer system is an excellent candidate for automation equipments which require precise synchronization based on Ethernet at a comparatively low price.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Chen, G., Ye, D., Che, R.S., 2007. Developing Trend of Industrial Fieldbus Control System. Proc. 8th Int. Conf. on Electronic Measurement and Instruments, Xi’an, China, p.1765–1768. [doi:10.1109/ICEMI.2007.4350563]

  • Chu, J., 2006. Deterministic and Real-time Communication over Ethernet in EPA Control System. Sixth World Congress on Intelligent Control and Automation, Dalian, China. p.XI–XII. [doi:10.1109/WCICA.2006.1713395]

  • Dopatka, F., Wismuller, R., 2007. Design of a Realtime Industrial-Ethernet Network Including Hot-pluggable Asynchronous Devices. IEEE Int. Symp. on Industrial Electronics, p.1826–1831. [doi:10.1109/ISIE.2007.4374883]

  • Feng, D.Q., Huang, W.J., Jin, J.X., Chu, J., 2003. EPA-based Open Network Control System. Proc. 4th Int. Conf. on Control and Automatio, Montreal Canada, p.976–980.

  • IEEE Std 1364, 2006. Behavioural Languages—Part 4: Verilog Hardware Description Language.

  • Limal, S., Potier, S., Denis, B., Lesage, J.J., 2007. Formal Verification of Redundant Media Extension of Ethernet PowerLink. IEEE Conf. on Emerging Technologies and Factory Automation, Patras, Greece, p.1045–1052. [doi:10.1109/EFTA.2007.4416898]

  • Pang, H., Wang, L., Ma, J.L., 2007. Research of Monitoring and Configuration Platform in Foundation Fieldbus Control System. IEEE Int. Conf. on Integration Technology, Shenzhen, China, p.756–759. [doi:10.1109/ICITECHNOLOGY.2007.4290422]

  • Paula, D., 2005. Real Time Ethernet 2 Introduction to Real-time Solutions Available to Industry. Industrial Ethernet University. Http://www.industrialethernetu.com/courses/402_4.htm

  • Xu, J., Fang, Y., 2005. Development of Fieldbus Master Integrated with Ethernet Interface. IEEE Conf. on Emerging Technologies and Factory Automation, Catania, Italy, p.1–4. [doi:10.1109/ETFA.2005.1612671]

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ming-xu Huo.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lian, Yp., Han, Y., Huo, Mx. et al. Design and FPGA verification of a novel reliable real-time data transfer system. J. Zhejiang Univ. Sci. A 9, 1406–1410 (2008). https://doi.org/10.1631/jzus.A0720123

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1631/jzus.A0720123

Key words

Document code

CLC number

Navigation