Skip to main content
Log in

Elastic-plastic study on high building with SRC transferring story

  • Published:
Journal of Zhejiang University-SCIENCE A Aims and scope Submit manuscript

Abstract

A new type of transferring structure for steel reinforced concrete (SRC) beams is used in high building. The pushover analysis method was used to study the failure mechanism and ductility of SRC transferring structure through consulting pseudo-static test results for the structure. And, the occurrence order and position of the plastic hinge, the weak story and seismic capacity of high building with SRC transferring story were also studied through consulting shaking table test results for the high building, showing that the seismic behavior of high building with SRC transferring story is good.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Fajfar, P., 1999. Capacity spectrum method based on inelastic demand spectra. Earthquake Engng. and Struct. Dyn., 28(7):979–993. [doi: 10.1002/(SICI) 1096-9845(199909)28:9<979::AID-EQE850>3.0.CO;2-1]

    Article  Google Scholar 

  • Fu, C.G., Liang, S.T., Ma, H., 2000. Experiment on seismic performance of SRC transferring story. Building Structures, 30(4):61–64 (in Chinese).

    Google Scholar 

  • Li, K.L., Hou, N., Yie, X.G., 2001. Nonlinear analysis of 3D models and application in research of a building damaged in earthquake. Building Structure, 3:53–61 (in Chinese).

    Google Scholar 

  • Liu, J.S., 2004. Study on Seismic Performance of Structure with a Truss Located at a Higher Level. Ph.D Thesis, Zhejiang University, Hangzhou, p. 77–105 (in Chinese).

    Google Scholar 

  • Liu, J.J., Zhang, J., Lv, Z.T., 2002. Application of push-over method in simulating pseudo-static experiment. Building Structures, 32(8):63–65 (in Chinese).

    Google Scholar 

  • Moghadam, A.S., Tso, W.K., 2000. 3-D pushover analysis for damage assessment of buildings. JSEE, 2(3):23–30.

    Google Scholar 

  • Saiidi, M., Sozen, M.A., 1981. Simple nonlinear seismic analysis of R/C structures. Journal of the Structural Division, ASCE, 107(ST5):937–951.

    Google Scholar 

  • SICABR (Structure Institute of China Academy of Building Research), 2003. Research on the Shaking Table Test of the Constructing High Building for the Production Management at Zhejiang Province Electric Company. China Academy of Building Research, p.65–67 (in Chinese).

  • Tso, W.K., Moghadam, A.S., 1998. Pushover procedure for seismic analysis of building. Progress in Structural Engineering and Materials, 1(3):337–344. [doi: 10.1002/pse.2260010317]

    Article  Google Scholar 

  • Vidie, T., Fajfar, P., Fischinger, M., 1994. Consistent inelastic design spectra: Strength and displacement. Earthquake Engng. and Struct. Dyn., 23(4):507–521.

    Google Scholar 

  • Wang, M.F., Zhou, X.Y., 2002. A practical method for nonlinear seismic responses of RC framewall structure. China Civil Engineering Journal, 35(6):32–38 (in Chinese).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Li, Yr., Qiu, T. & Sun, Bn. Elastic-plastic study on high building with SRC transferring story. J. Zhejiang Univ. - Sci. A 7, 407–414 (2006). https://doi.org/10.1631/jzus.2006.A0407

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1631/jzus.2006.A0407

Keywords