Skip to main content
Log in

Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients

  • Published:
Journal of Zhejiang University SCIENCE B Aims and scope Submit manuscript

Abstract

Objective: To compare a new device (Innocor) for non-invasive measurement of cardiac output (CO) by foreign gas rebreathing method with conventional techniques used in the measurements of cardiac function. Methods: Cardiac outputs measured by Innocor (CORB) were compared with CO obtained by echocardiography (COEC), Swan-Ganz thermodilution (COTD), and left ventricle radiography (COLVR) in 34 patients subjected to cardiac catheterization. Values obtained from the four methods were analyzed by linear regression and paired values were compared by the method of Bland and Altman in SPSS. Results: There was strong positive correlation (r=0.94) between Innocor cardiac output values and the corresponding values obtained by thermodilution and between COEC and COLVR values. Thermodilution appears to overestimate cardiac output when compared to the values obtained with Innocor by (0.66±0.22) L/min (P<0.0001). There was no correlation between data obtained by Innocor and the corresponding COEC and COLVR values. Conclusion: Innocor CORB is an easy, safe and well established method for non-invasive measurement of cardiac output with good prospects for clinical application in heart disease patients.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Clemensen, P., Christensen, P., Norsk, P., Gronlund, J., 1994. A modified photo-and magnetoacoustic multigas analyzer applied in gas exchange measurements. J. Appl. Physiol., 76(6):2832–2839.

    PubMed  CAS  Google Scholar 

  • Friedman, M., Wilkins, S.A.Jr., Rothfeld, A.F., Bromberg, P.A., 1984. Effect of ventilation and perfusion imbalance on inert gas rebreathing variables. J. Appl. Physiol., 56(2):364–369.

    PubMed  CAS  Google Scholar 

  • Gabrielsen, A., Videbaek, R., Schou, M., Damgaard, M., Kastrup, J., Norsk, P., 2002. Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique. Clinical Science, 102:247–252. doi:10.1042/CS20010158.

    Article  PubMed  Google Scholar 

  • Hoeper, M.M., Maier, R., Tongers, J., Niedermeyer, J., Hohlfeld, J.M., Hamm, M., Fabel, H., 1999. Determination of cardiac output by the Fick method, thermodilution, and acetylene rebreathing in pulmonary hypertension. Am. J. Respir. Crit. Care Med., 160:535–541.

    PubMed  CAS  Google Scholar 

  • Kallay, M.C., Hyde, R.W., Smith, R.J., Rothbard, R.L., Schreiner, B.F., 1987. Cardiac output by rebreathing in patients with cardiopulmonary diseases. J. Appl. Physiol., 63(1):201–210.

    PubMed  CAS  Google Scholar 

  • Morten, D., Peter, N., 2005. Effects of ventilation on cardiac output determined by inert gas rebreathing. Clinical Physiology and Functional Imaging, 25(3):142–147. doi:10.1111/j.1475-097X.2005.00602.x.

    Article  Google Scholar 

  • Petrini, M.F., Peterson, B.T., Hyde, R.W., 1978. Lung tissue volume and blood flow by rebreathing: theory. J. Appl. Physiol., 44:795–802.

    PubMed  CAS  Google Scholar 

  • Reinhart, M.E., Hughes, J.R., Kung, M., Abraham, W.M., Ahmed, T., Eyre, P., Wanner, A., 1979. Determination of pulmonary blood flow by the rebreathing technique in airflow obstruction. Am. Rev. Respir. Dis., 120:533–540.

    PubMed  CAS  Google Scholar 

  • Sackner, M.A., Greeneltch, D., Heiman, M.S., Epstein, S., Atkins, N., 1975. Diffusing capacity, membrane diffusing capacity, capillary volume, pulmonary tissue volume, and cardiac output measured by a rebrathing technique. Am. Rev. Respir. Dis., 111:157–165.

    PubMed  CAS  Google Scholar 

  • Sackner, M.A., 1987. Measurement of cardiac output by alveolar gas exchange. Handb. Physiol. Sect. 3 Respir. Syst. Gas Exchange, 4:233–255.

    Google Scholar 

  • Sweet, R.L., Moraski, R.E., Russell, R.O.Jr., Rackley, C.E., 1975. Relationship between echocardiography, cardiac output, and abnormally contracting segments in patients with ischemic heart disease. Circulation, 52:634–641.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wang Jian-an  (王建安).

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dong, L., Wang, Ja. & Jiang, Cy. Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients. J. Zhejiang Univ. - Sci. B 6, 1157–1162 (2005). https://doi.org/10.1631/jzus.2005.B1157

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1631/jzus.2005.B1157

Key words

CLC number

Navigation