Skip to main content
Log in

Analysis of superheater’s pipe wall overtemperature by fault tree diagnose

  • Energy & Environment Engineering
  • Published:
Journal of Zhejiang University-SCIENCE A Aims and scope Submit manuscript

Abstract

After research on a 2000t/h subcritical forced-circulation balanced ventilation were applied boiler and the structure and operation of its auxiliary system builds up this heat transfer model of a superheater’s pipe wall and analyze the effect of primary factors on the overtemperature of the pipe wall. Fault tree structure was used to uncover the multiplayer logic between the overtemperature of the superheater’s pipe wall and the faults.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

References

  • Cheng Leming, Shi Zhenlun, Luo Zhongyang et al., 2002, Temperature distributions in a finned water wall tube of a circulating fluidized bed boiler.Power Engineering,22(2): 1674 (in Chinese).

    Google Scholar 

  • Guan Bisheng, 1996. Prevent fuel from reburning at rear part of large size boiler.China Electric Power.29(5): 43 (in Chinese).

    Google Scholar 

  • Huang Wenhu, Xia Songbo, Liu Ruiyan et al., 1996. Diagnosis Theory Tech nology & Application for Equipment Breakdown. Science Press, Beijing, p. 192.

    Google Scholar 

  • Jin An, 1999. Over temperature reason and modified measures of superheater and reheater in tangentially fired furnace.Power System Engineering.15(2): 25 (in Chinese).

    Google Scholar 

  • Jin Hanhui, Xia Jun, Fan Jianren et al., 2002. Simulating confined swirling gas-solid two phase jet.Journal of zhejiang University SCIENCE,3(2): 157.

    Article  Google Scholar 

  • Li Deying, Ni Weidou, 1998. Generalized fault tree knowledge representation method for power plant boiler fault diagnostic systems,Journal of Tsinghua University.38(7): 74 (in Chinese).

    Google Scholar 

  • Li Jin, Wang Yao, Liu Feng et al., 2001. Overheating analysis and recreation plant for the primary reheater of a 670 t/h coal-fired boiler.Power Engineering,21 (6): 1507 (in Chinese).

    Google Scholar 

  • Wang Ying, Wu Shaohua, Qin Yukun, 1998. Mechanism and preventive measures of coal-fired boiler tube explosion for power plants.Power System Engineering,14 (5): 27 (in Chinese).

    Google Scholar 

  • Yan Weiping, Chen Huagui, Ye Xuemin et al., 2002. Calibration method for calculating tube wall temperature of the high temperature convective bheat transfer surface in the utility boilers.Power Engineering,22(3): 1768 (in Chinese).

    Google Scholar 

  • Zhu Jizhou, 1989. Principle of Fault Tree and Its Application. Xi’an Jiaotong University Press, Xi’an, p. 30.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

De-ren, S., Hao-ren, R., Jian-hong, C. et al. Analysis of superheater’s pipe wall overtemperature by fault tree diagnose. J. Zhejiang Univ.-Sci. 3, 391–394 (2002). https://doi.org/10.1631/BF02839478

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1631/BF02839478

Key words

Document code

CLC number

Navigation