Aerodynamic stability of cable-supported bridges using CFRP cables

  • Zhang Xin-jun 
  • Ying Lei-dong 
Article

Abstract

To gain understanding of the applicability of carbon fiber reinforced polymer (CFRP) cable in cable-supported bridges, based on the Runyang Bridge and Jinsha Bridge, a suspension bridge using CFRP cables and a cable-stayed bridge using CFRP stay cables are designed, in which the cable’s cross-sectional area is determined by the principle of equivalent axial stiffness. Numerical investigations on the aerodynamic stability of the two bridges are conducted by 3D nonlinear aerodynamic stability analysis. The results showed that as CFRP cables are used in cable-supported bridges, for suspension bridge, its aerodynamic stability is superior to that of the case using steel cables due to the great increase of the torsional frequency; for cable-stayed bridge, its aerodynamic stability is basically the same as that of the case using steel stay cables. Therefore as far as the wind stability is considered, the use of CFRP cables in cable-supported bridges is feasible, and the cable’s cross-sectional area should be determined by the principle of equivalent axial stiffness.

Key words

Cable-supported bridges Carbon fiber reinforced polymer (CFRP) cable Aerodynamic stability 

CLC number

U448.25 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Chen, A.R., Song, J.Z., 2000. Wind-resistant Study on the Runyang Bridge over the Yangtze River. Research Report of Tongji University, Shanghai, China (in Chinese).Google Scholar
  2. Cheng, S.H., 1999. Structural and Aerodynamic Stability Analysis of Long-span Cable-stayed Bridges. Ph.D Thesis, Carleton University, Ottawa, Canada.Google Scholar
  3. Fang, M.S., Xiang, H.F., 1999. Aerostatic behavior of large-span suspension bridge with advanced composite cables. Journal of Chongqing Jiaotong University, 18(3):1–6 (in Chinese).Google Scholar
  4. Kao, C.S., Kou, C.H., 2005. Study on the long-span cable-stayed bridges with cable fiber composite cables. Asia Pacific Review of Engineering Science and Technology, 3:297–318.Google Scholar
  5. Kao, C.S., Kou, C.H., Xie, X., 2006. Static instability analysis of long-span cable-stayed bridges with carbon fiber composite cable under wind load. Tamkang Journal of Science and Engineering, 9(2):89–95.Google Scholar
  6. Kou, C.H., Xie, X., Gao, J.S., Huang, J.Y., 2005. Static behavior of long-span cable-stayed bridges using carbon fiber composite cable. Journal of Zhejiang University (Engineering Science), 39(1):137–142 (in Chinese).Google Scholar
  7. Kremmidas, S.C., 2004. Improving Bridge Stay Cable Performance Under Static and Dynamic Loads. Ph.D Thesis, University of California, San Diego, America.Google Scholar
  8. Meier, U., 1992. Carbon fiber reinforced polymers: modern materials in bridge engineering. Structural Engineering International, IABSE, 1:7–12.CrossRefGoogle Scholar
  9. Meier, U., Meier, M., 1996. CFRP finds in cable support for bridges. Modern Plastics, 26:87–89.Google Scholar
  10. Noisternig, J.F., 2000. Carbon fiber composites as stay cables for bridges. Applied Composite Materials, 7(2/3):139–150. [doi:10.1023/A:1008946132034]CrossRefGoogle Scholar
  11. Nonuaki, T., Tadao, H., Tatsuya, M., Nobuo, N., 1999. Study on aerodynamic stability and preliminary design of dual cable suspension bridges using advanced composites. Transactions of the Japan Society for Computational Engineering and Science, JSCES, 1:89–94.Google Scholar
  12. Song, J.Z., 1998. Wind-resistant Study on the Jinsha Bridge over the Yangtze River. Research Report of Tongji University, Shanghai, China (in Chinese).Google Scholar
  13. Xiang, H.F., Ge, Y.J., 2002. Refinements on aerodynamic stability analysis of super long-span bridges. Journal of Wind Engineering and Industrial Aerodynamics, 90(12–15):1493–1515. [doi:10.1016/S0167-6105(02)00266-0]CrossRefGoogle Scholar
  14. Xie, X., Gao, J.S., Kou, C.H., Huang, J.Y., 2005. Structural dynamic behavior of long-span cable-stayed bridges using carbon fiber composite cable. Journal of Zhejiang University (Engineering Science), 39(5):728–733 (in Chinese).Google Scholar
  15. Zhang, X.J., Xiang, H.F., Sun, B.N., 2002. Nonlinear aerostatic and aerodynamic analysis of long-span suspension bridges considering wind-structure interactions. Journal of Wind Engineering and Industrial Aerodynamics, 90(9):1065–1080. [doi:10.1016/S0167-6105(02)00251-9]CrossRefGoogle Scholar