Skip to main content

TableĀ 3 Comparison between the E0 values of the numerical simulation and the local static MOE derived experimentally for Series A and B. CoV: Coefficient of Variation

From: Structural performance of a novel Interlocking Glued Solid Timber system

Joist groupAB
Solid joistGlued joist
Numerical simulationExperimental (static)Experimental to numericalNumerical simulationExperimental (static)Experimental to numerical
114,96113,7001.09979297001.01
212,77612,9000.9911,48211,7000.98
312,49112,3001.0215,72915,2001.03
417,70217,0001.0414,00114,3000.98
517,29817,4000.9916,92216,9001.00
Mean (MPa)14,886.514,7001.0313,317.913,5001.00
CoV0.160.140.040.230.190.02