Abstract
Twenty-six circular RC columns were tested under axial compression to explore the confinement effects of fiber reinforced polymer (FRP) sheets on the performance of heat-damaged short columns. The effects of increased column slenderness, level of heat-induced damage and stiffness of the FRP wrapping system were examined. Columns with l/r ratios of 12.5 and 18.75 were subjected to 500 °C for 1, 2 and 3 h. Eighteen heat-damaged columns were wrapped using unidirectional carbon and glass FRP sheets over their full heights. Test results showed that FRP wrapping significantly enhanced the axial resistance, toughness, ductility and deformation capacity of the heat-damaged columns but failed to restore their axial stiffness. Increasing the stiffness of the FRP jacket resulted in further enhancements in axial resistance, stiffness and toughness of the heat-damaged columns while adversely affecting their ductility. Carbon fiber reinforced polymer jackets with a confinement modulus of 0.65 GPa managed to reinstate, and even exceed, the original strength of heat-damaged columns. The effectiveness of FRP confinement of heat-damaged columns increased significantly with increasing damage level and decreasing column slenderness. The heat- and confinement-induced increases in column slenderness had no tangible effects on buckling stability of the test columns that were originally of low slenderness.
Similar content being viewed by others
References
Lie TT, Rowe TJ, Lin TD (1984) Residual strength of fire-exposed reinforced concrete columns. Eval Repair Fire Damage Concrete, ACI, SP 92–9:153–174
Lie TT, Lin TD (1985) Fire performance of reinforced concrete columns. Fire Saf 882:176–205
Lin CH, Tsai CS (1990) Deterioration of strength and stiffness of reinforced concrete columns after fire. J Chin Inst Eng 13(3):273–283
Kodur VR (1999) Fibre reinforced concrete for enhancing the structural fire resistance of columns. Fibre-Struct Appl Fibre-Reinf Concr ACI SP 182:215–234
Kodur VKR, McGrath R (2001) Performance of high strength concrete columns under severe conditions. In: Proceedings of the third international conference on concrete under severe conditions, Vancouver, Canada, pp. 254–268
Kodur VKR, Cheng FP, Wang TC (2003) Effect of strength and fiber reinforcement on the fire resistance of high strength concrete columns. ASCE J Struct Eng 129(2):253–259
Kodur VR, McGrath RC (2003) Fire endurance of high strength concrete columns. Fire Technol Special Issue 39(1):73–87
Ali F, Nadjai A, Silcock G, Abu-Tair A (2004) Outcomes of a major research on fire resistance of concrete columns. Fire Saf J 39(6):433–445
Jau WC, Huang KL (2008) A Study of reinforced concrete corner columns after fire. Cem Concr Compos 30(7):622–638
Chen YH, Chang YF, Yao GC, Sheu MS (2009) Experimental research on post-fire behaviour of reinforced concrete columns. Fire Saf J 44(5):741–748
Yaqub M, Bukhari I, Ghani U (2013) Assessment of residual strength based on estimated temperature of post-heated RC columns. Mehran Univ Res J Eng Technol 32(1):55–70
El-Shaer M (2014) Structural analysis for concrete columns subjected to temperature. ACTA TECHNICA CORVINIENSIS-Bulletin of Engineering, Tome VII, Fascicule 2 (April–June) ISSN: 2067-3809
Hertz K (2005) Concrete strength for fire safety design. Mag Concr Res 57(8):445–453
Abrams MS (1977) Compressive strength of concrete at temperatures to 1600F. PCA, Research and Development Bulletin, RD016.10T
Kowalski R (2010) Mechanical properties of concrete subjected to high temperature. Arch Civil Eng Environ 3(2):61–70
Purkiss JA, Li Long-Yuan (2013) Fire safety engineering design of structures, 3rd edn. CRC Press, Boca Raton
Yaqub M, Bailey CG (2011) Repair of fire damaged circular reinforced concrete columns with FRP composites. Constr Build Mater 25(1):359–370
Yaqub M, Bailey CG, Nedwell P (2011) Axial capacity of post-heated square columns wrapped with FRP composites. Cem Concr Compos 33(6):694–701
Yaqub M, Bailey CG (2011) Cross sectional shape effects on the performance of post-heated reinforced concrete columns wrapped with FRP composites. Compos Struct 93(3):1103–1117
Bisby LA, Chen JF, Li SQ, Stratford TJ, Cueva N, Crossling K (2011) Strengthening fire-damaged concrete by confinement with fibre-reinforced polymer wraps. Eng Struct 33(12):3381–3391
Yaqub M, Bailey CG (2012) Seismic performance of shear critical post-heated reinforced concrete square columns wrapped with FRP composites. Constr Build Mater 34:457–469
Bailey C, Yaqub M (2012) Seismic strengthening of shear critical post-heated circular concrete columns wrapped with FRP composite jackets. Compos Struct 94(3):851–864
Al-Kamaki Y, Al-Mahaidi R (2013) Compressive strength of concrete damaged by elevated temperature and confined by CFRP fabrics. In: Proceedings of 4th Asia-Pacific conference on frp in structures, APFIS Melbourne, Australia
Yaqub M, Bailey CG, Nedwell P, Khan QUZ, Javed I (2013) Strength and stiffness of post-heated columns repaired with ferrocement and fibre reinforced polymer jackets. Compos Part B 44(1):200–211
Tahir MF, Yaqub M, Bukhari I, Tufail RF, Tahir A (2013) Effect of carbon fiber reinforced polymer confinement on the fire damaged and un-heated reinforced concrete square columns. Life Sci J 10(12s):791–799
Al-Nimry H, Haddad R, Afram S, Abdel-Halim M (2013) Effectiveness of advanced composites in repairing heat-damaged RC columns. Mater Struct 46(11):1843–1860
Roy A, Sharma U, Bhargava P (2013) Strengthening of heat damaged reinforced concrete cylinders. In: Proceedings of the international conference on application of structural fire engineering, Prague, Czech Republic
Al-kamaki Y, Al-Mahaidi R, Bennetts ID (2014) Confinement of heat-damaged RC circular columns using CFRP fabrics. In: Proceedings of 23rd Australasian conference on mechanics of structures and materials, Byron Bay, NSW, vol. I, pp. 477–482
Roy A, Sharma U, Bhargava P (2014) Strengthening of heat damaged reinforced concrete short columns. J Struct Fire Eng 5(4):381–398
Roy A, Sharma U, Bhargava P (2016) Confinement strengthening of heat-damaged reinforced concrete columns. Mag Concr Res 68(6):291–304
Al-Kamaki Y, Al-Mahaidi R, Bennets ID (2015) Experimental and numerical study of the behaviour of heat-damaged RC circular columns confined with CFRP fabric. Compos Struct 133:679–690
Ghanem A (2015) Repair of heat-damaged circular reinforced concrete columns using fiber reinforced polymers. Dissertation, Jordan University of Science and Technology
De Lorenzis L, Tamuzs V, Tepfers R, Valdmanis V, Vilks U (2004) Stability of CFRP-confined columns. In: Proceedings of 1st international conference on innovative materials and technologies for construction and restoration, Lecce, Italy, pp. 327–342
Tamuzs V, Tepfers R, Zile E, Valdmanis V (2007) Stability of round concrete columns confined by composite wrappings. Mech Compos Mater 43(5):445–452
Tamuzs V, Valdmanis V, Tepfers R, Gylltoft K (2008) Stability analysis of CFRP-wrapped concrete columns strengthened with external longitudinal CFRP sheets. Mech Compos Mater 44(3):199–208
Tamuzs V, Valdmanis V, Gylltoft K, Tepfers R (2007) Behavior of CFRP-confined concrete cylinders with a compressive steel reinforcement. Mech Compos Mater 43(3):191–202
Tao Z, Teng JG, Han LH, Lam L (2004) Experimental behaviour of FRP-confined slender RC columns under eccentric loading. In: Proceedings of 2nd international conference on advanced polymer composites for structural applications in construction, Guildford, UK, pp. 203–212
Fitzwilliam J, Bisby LA (2010) Slenderness effects on circular CFRP confined reinforced concrete columns. J Compos Constr 14(3):280–288
Bisby LA, Ranger M (2010) Axial-flexural interaction in circular FRP-confined reinforced concrete columns. Constr Build Mater 24(9):1672–1681
Jiang T (2008) FRP-confined RC columns: analysis, behaviour, and design. Dissertation, Hong Kong Polytechnic University
Jiang T, Teng J (2013) Behavior and design of slender FRP-confined circular RC columns. Compos Constr 17(4):443–453
Ranger M, Bisby L (2007) Effects of load eccentricities on circular FRP confined reinforced concrete columns. In: Proceedings of 8th international symposium on fiber-reinforced polymer reinforcement for concrete structures, University of Patras, Greece
Hadi M, Yazici V (2010) Behaviour of FRP wrapped circular reinforced concrete columns. Challenges, opportunities and solutions in structural engineering and construction. In: Ghafoori (ed.) Taylor & Francis Group, London, ISBN 978-0-415-56809-8
Jiang T, Teng JG (2012) Theoretical model for slender FRP-confined circular RC columns. Constr Build Mater 32:66–76
De Lorenzis L, Tepfers R (2004) Applicability of FRP confinement to strengthen concrete columns. Nordic Concrete Research No. 31, The Nordic Concrete Federation 1/2004, Oslo, pp. 64–72
Jiang T, Teng JG (2012) Slenderness limit for short FRP-confined circular RC columns. Compos Constr 16(6):650–661
Siddiqui NA, Alsayed SH, Al-Salloum YA, Iqbal RA, Abbas H (2014) Experimental investigation of slender circular RC columns strengthened with FRP composites. Constr Build Mater 69:323–334
ISIS Canada (2001) Design manual no. 4: strengthening reinforced concrete structures with externally-bonded fiber reinforced polymers. Intelligent sensing for innovative structures, Winnipeg, Canada
ACI 318-14 (2014) Building code requirements for structural concrete (ACI 318-14) and commentary. American Concrete Institute, Farmington Hills
ACI 211.1-91 (1991) Standard practice for selecting proportions for normal, heavyweight and mass concrete (reapproved 2009). American Concrete Institute, Farmington Hills
Eurocode 2 (EN1992-1-2) (2004) Design of concrete structures. Part 1.2: general rules—structural fire design. Commission of European Communities, Brussels
ASCE, Structural Fire Protection (1992) Manual No. 78, ASCE committee on fire protection, structural division. American Society of Civil Engineers, New York
Neves IC, Rodrigues JPC, Loureiro AP (1996) Mechanical properties of reinforcing and prestressing steels after heating. J Mater Civ Eng 8(4):189–194
Tolentino E, Lameiras FS, Gomes AM, Rigo da Silva CA, Vasconcelos WL (2002) Effects of high temperature on the residual performance of Portland cement concretes. Mater Res 5(3):301–307
Wickstrom ULF (1986) A very simple method for estimating temperature in fire exposed concrete structures. Fire Technology, Technical Report SP-RAPP, vol 46
Zhang B, Bicanic N, Pearce CJ, Balabanic G (2000) Assessment of toughness of concrete subject to elevated temperatures from complete load–displacement curve-Part II: experimental investigations. ACI Mater J 97(5):556–566
Lam L, Teng JG (2003) Design-oriented stress–strain model for FRP-confined concrete. Constr Build Mater 17(6–7):471–489
Benzaid R, Mesbah H, Chikh N (2010) FRP-confined concrete cylinders: axial compression experiments and strength model. Reinf Plast Compos 29(16):2469–2488
Chastre C, Silva M (2010) Monotonic axial behavior and modelling of RC circular columns confined with CFRP. Eng Struct 32(8):2268–2277
Matthys S, Toutanji H, Taerwe L (2006) Stress–strain behavior of large-scale circular columns confined with FRP composites. Struct Eng 132(1):123–133
Teng JG, Jiang T, Lam L, Luo YZ (2009) Refinement of a design-oriented stress–strain model for FRP-confined concrete. Compos Constr 13(4):269–278
ACI 440.2R (2008) Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures. American Concrete Institute, Farmington Hills
Acknowledgements
The work presented in this article was funded by the Deanship of Research at Jordan University of Science and Technology under Grant No. 2015/45.
Funding
The Deanship of Scientific Research at Jordan University of Science and Technology funded the investigation subject of the paper. The sponsor had no role in the study design, in the collection, analysis and interpretation of data, in the writing of the report, and in the decision to submit the paper for publication.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Al-Nimry, H., Jawarneh, M. Effects of increased slenderness in short heat-damaged RC columns confined with FRP composites. Mater Struct 50, 95 (2017). https://doi.org/10.1617/s11527-016-0965-7
Received:
Accepted:
Published:
DOI: https://doi.org/10.1617/s11527-016-0965-7