Abstract
Cold-formed steel built-up sections are commonly used as compression elements to carry larger loads and over longer spans when a single individual section is insufficient. This paper reports a numerical study of the cold-formed steel built-up web stiffened lipped channel sections under axial compression. The built-up sections are formed by two identical lipped channels placed back to back with batten plates and are connected by self-driving screw. The Finite element model is developed by ABAQUS software and the model is validated with the results available in the literature. Three types of web stiffened lipped channel cross section have been chosen for the study, based on the AISI-S100:2007 Geometric limitations. The parametric study is extended by the validated model for various slenderness ratios. The column strength predicted by the finite element analysis is compared with the design column strengths predicted by direct strength method (DSM). Based on this study a recommendation is proposed to DSM.
Similar content being viewed by others
References
Johnson B.G (1971). Spaced Steel Columns. J Struct Div, ASCE, 97.ST5, 1465-1479
Rondal J, Niazi M (1990) Stability of Built-up Beams and Columns with Thin-walled Members, Internat. Coll. Stability of Steel Structures, Budapest, Hungary
Aslani F, Goel SC (1991) An analytical criterion for buckling strength of built-up compression members. Eng J 28(4):159–168
Temple MC, Elmahdy G (1993) An examination of the requirements for the design of built-up compression members in the North American and European standards. Can J Civ Eng 20(6):895–909
Schafer BW, Pekoz T (1998) Computational modelling of cold-formed steel: characterizing geometric imperfections and residual stress. J Constr Steel Res 47:193–210
Sherman DR, Yura JA (1998) bolted double angle compression members. J Construct Steel Res 46(1–3):470–471
Salem AH, El Aghoury M, El Dib FF, Hanna MT (2004) Ultimate capacity of I-slender section columns. J Constr Steel 60:1193–1211
AISC-LRFD (2005) Load and resistance factor design specifications for structural steel buildings, AISC, Chicago, Illinois
AS/NZS 4600 (2005) Australian/New Zealand Standard––Cold formed steel structures, Sydney, Australia
Stone TA, LaBoube RA (2005) Behavior of cold-formed steel built-up I-sections. Thin-Walled Struct 43:1805–1817
Lue DM, Yen Tsong, Liu Jui-Ling (2006) Experimental investigation on built-up columns. J Constr Steel 62:1325–1332
Sukumar S, Parameswaran P, Jayagopal LS (2006) Local-,distortional-,and Euler buckling of thin walled built-up open cross-sections under compression. J Struct Eng––Madras 32(6):447–454
AISI-S100 (2007) North American specification for the design of cold-formed steel structural members, AISI, Washington, DC, USA
Young B (2008) Design of cold-formed steel built-up closed sections with inter- mediate stiffeners. J Struct Eng 134:727
Hashemi Hosseini B, Jafari MA (2009) Experimental evaluation of elastic critical load in battened columns. J Constr Steel Res 65:125–131
Whittle J, Ramseyer C (2009) Buckling capacities of axially loaded, cold-formed, built-up C-channels. Thin-Walled Struct 47:190–201
El Aghoury MA, Salem AH, Hanna MT, Amoush EA (2010) Experimental investigation for the behaviour of battened beam-columns composed of four equal slender angles. Thin-Walled Struct 48(9):669–683
Ting TCH, Lau HH (2011) Compression test on cold-formed steel built-up back to back channels stub columns. Adv Mater Res 201–203:2900–2903
El Aghoury MA, Salem AH, Hanna MT, Amoush EA. (2012) Ultimate capacity of battened columns composed of four equal slender angles. Thin-Walled Struct, December
Georgieva IB, Schueremans L, Pyl L (2012) Experimental investigation of built-up double-Z members in bending and compression. Thin-Walled Struct 53(4):48–57
Georgieva IB, Schueremans L, Pyl L (2012) Composed columns from cold-formed steel Z-profiles. Experiments and code-based predictions of the overall resistance. Eng Struct 37(4):125–134
Anbarasu M, Sukumar S (2013) Study on the effect of ties in the intermediate length cold formed steel (CFS) columns. Struct Eng Mech Int J 46(3):323–335
Anbarasu M, Bharathkumar P, Sukumar S (2014) Study on the capacity of cold-formes steel built-up battened columns under axial compression. Latin Am J Solids Struct 11(12):2271–2283
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Anbarasu, M., Kanagarasu, K. & Sukumar, S. Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns. Mater Struct 48, 4029–4038 (2015). https://doi.org/10.1617/s11527-014-0463-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1617/s11527-014-0463-8