Determining Canine Blood and Human Blood Composition by Congealing Microliter Drops into Homogeneous Thin Solid Films (HTSFs) via HemaDrop™

  • Published:
MRS Advances Aims and scope Submit manuscript

Abstract

Accurate analysis of microliter blood samples can improve patient care during medical testing and forensics. Patients can suffer from anemia due to the larger volume required for blood tests, 7 milliliters per vial. Attempts at analysis of nanoliter blood samples by Theranos have systematic errors > 10%, higher than medically acceptable thresholds. Our research aims to analyze composition of microliters of blood. This research investigates accuracy of analyzing blood via HemaDrop™, a patented technique to create a Homogenous Thin Solid Film (HTSF) on super-hydrophilic and hyper-hydrophilic surfaces with 5 microliter droplets of blood. To investigate HemaDrop™’s accuracy, Ion Beam Analysis (IBA) is conducted on dried blood spots (DBS) and HTSFs from congealed blood drops on HemaDrop™-treated samples. HTSFs are observed via optical microscopy to compare uniformity, precipitation, and phase separation. DBSs and HTSFs are compared via optical microscopy for canine blood and human blood. After drying uncoated samples, canine and human blood DBSs exhibit cratering, phase separation, and lack of uniformity. Conversely, HTSFs are uniform, exhibiting no cratering and little phase separation. Next, IBA demonstrates that HTSFs of canine and human blood solidified on super-hydrophilic and hyper-hydrophilic coatings yield spectra where species and electrolytes can be identified, unlike on DBSs. The damage curve method enables extracting accurate blood composition for elements, accounting for IBA damage. Relative error in blood elemental composition is within the 10% medical threshold. While both produced films within the 10% threshold, hyper-hydrophilic coatings eliminated phase separation from serum observed in HTSFs on super-hydrophilic coatings. HemaDrop™ provides consistent measurements independent of sample, showing HTSFs from μL blood drops are uniform, reproducible, and free of phase separation. Thus, HemaDrop™ allows for analysis in vacuum from congealed blood drops and expands the range of techniques to identify elements and molecules.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Johannes Buettner, in Senses, Sensors and Systems, (Imprint unknown, Basel, 2004).

  2. M. Zhi, E. L. Ding, J. Theisen-Toupal, J. Whelan, R. Arnaout, PLoS ONE 8, e78962 (2013).

    Google Scholar 

  3. J. G. van der Bom, S. C. Cannegieter, JTH, 13, 1157 (2015).

    Google Scholar 

  4. A. C. Salisbury, Arch. Intern. Med., 171, 1646 (2011).

    Article  Google Scholar 

  5. R. N. Thakkar, D. Kim, et al., Am. J. Clin. Pathol., 143, 393 (2015).

    Article  Google Scholar 

  6. B. A. Kidd, G. Hoffman, N. Zimmerman, L. Li, J. W. Morgan, P. K. Glowe, G. J. Botwin, S. Parekh, et al., J. Clin. Invest., 126, 1734 (2016).

    Article  Google Scholar 

  7. John P. Greer, in Wintrobe’s Clinical Hematology, (Lippincott Williams & Wilkins, Philadelphia, 2014).

  8. Y. Pershad, N. Herbots, et al., MRS Adv. 1 (29), 2133–2139 (2016).

    Article  CAS  Google Scholar 

  9. Sharmila M. Mukhopadhyay, in Sample Preparation for Microscopic and Spectroscopic Characterization of Solid Surfaces, (John Wiley & Sons, Inc., Hoboken, 2003) p. 377–411.

  10. Q. Xing, N. Herbots, M. Hart, J. Bradley, B.J. Wilkens, D.A. Sell, C.H. Sell, et al., Applic. of Accel. in Res. and Ind. AIP Conf. Proc. 1336, 201–207 (2011).

    CAS  Google Scholar 

  11. K. Dar, T. Williams, R. Aitken, K. L. Woods, and S. Fletcher, BMJ, 310, 24 (1995).

    Article  CAS  Google Scholar 

  12. R. Fan, O. Vermesh, A. Srivastava, B. K. et al., Nat. Biotechnol., 26, 1373 (2008).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Pershad, Y., Herbots, N., Day, G. et al. Determining Canine Blood and Human Blood Composition by Congealing Microliter Drops into Homogeneous Thin Solid Films (HTSFs) via HemaDrop™. MRS Advances 2, 2451–2456 (2017). https://doi.org/10.1557/adv.2017.479

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1557/adv.2017.479

Navigation