Skip to main content
Log in

Modular 64x64 CdZnTe Arrays With Multiplexer Readout for High-Resolution Nuclear Medicine Imaging

  • Published:
MRS Online Proceedings Library Aims and scope

Abstract

We are developing modular arrays of CdZnTe radiation detectors for high-resolution nuclear medicine imaging. Each detector is delineated into a 64x64 array of pixels; the pixel pitch is 380 ptm. Each pixel is connected to a corresponding pad on a multiplexer readout circuit. The imaging system is controlled by a personal computer. We obtained images of standard nuclear medicine phantoms in which the spatial resolution of approximately 1.5 mm was limited by the collimator that was used. Significant improvements in spatial resolution should be possible with different collimator designs. These results are promising for high-resolution nuclear medicine imaging.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. J. Jaszczak and B. M. W. Tsui in Principles of Nuclear Medicine, 2nd ed., edited by H. N. Wagner.Jr., Z. Szabo, and J. W. Buchanan (Saunders, Philadelphia, 1995), p. 319.

  2. H. H. Barrett, J. D. Eskin, H. B. Barber. Phys. Rev. Lett. 75, 156 (1995).

    Article  CAS  Google Scholar 

  3. H. B. Barber, F. L. Augustine, H. H. Barrett, E. L. Dereniak, K. J. Matherson, T. J. Meyers, D. L. Perry, J. E. Venzon, J. M. Woolfenden, E. T. Young. Nucl. Instr. and Meth. A 353, 361 (1994).

    Article  CAS  Google Scholar 

  4. H. B. Barber, F. L. Augustine, H. H. Barrett, E. L. Dereniak, J. D. Eskin, D. G. Marks, K. J. Matherson, J. E. Venzon, J. M. Woolfenden, and E. T. Young in 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, edited by P. A. Moonier (IEEE Service Center, Piscataway, NJ, 1995) pp. 113–117.

  5. D. G. Marks, H. B. Barber, H. H. Barrett, E. L. Dereniak, J. D. Eskin, K. J. Matherson, J. M. Woolfenden, E. T. Young, F. L. Augustine, W. J. Hamilton, J. E. Venzon, B. A. Apotovsky, F. P. Doty. IEEE Trans. Nucl. Sci. 43, 1253 (1996).

    Article  CAS  Google Scholar 

  6. M. M. Rogulski, H. B. Barber, H. H. Barrett, R. L. Shoemaker, J. M. Woolfenden. IEEE Trans. Nucl. Sci. 40, 1123 (1993).

    Article  CAS  Google Scholar 

  7. F. L. Augustine, Nucl. Instr. and Meth. A 353, 201 (1994).

    Article  CAS  Google Scholar 

  8. K. J. Matherson, H. B. Barber, H. H. Barrett, J. D. Eskin, E. L. Dereniak, D. G. Marks, J. M. Woolfenden, E. T. Young, F. L. Augustine in 1997 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (IEEE Service Center, Piscataway, NJ), in press.

  9. H. B. Barber, E. L. Dereniak, J. D. Eskin, N. R. Hilton, D. G. Marks, K. J. Matherson, J. M. Woolfenden, and E. T. Young in 1997 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (IEEE Service Center, Piscataway, NJ), in press.

Download references

Acknowledgement

This work was supported by the U.S. Department of Health and Human Services under National Cancer Institute Grants P01 23417 and CA 75288.

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Woolfenden, J.M., Barber, H.B., Barrett, H.H. et al. Modular 64x64 CdZnTe Arrays With Multiplexer Readout for High-Resolution Nuclear Medicine Imaging. MRS Online Proceedings Library 484, 267–271 (1997). https://doi.org/10.1557/PROC-484-267

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1557/PROC-484-267

Navigation