Skip to main content
Log in

Development and application of an integrated system for monitoring ethanol content of fuels

  • Published:
Applied Biochemistry and Biotechnology Aims and scope Submit manuscript

Abstract

An automated flow injection analysis (FIA) system for quantifying ethanol was developed using alcohol oxidase, horseradish peroxidase, 4-aminophenazone, and phenol. A colorimetric detection method was developed using two different methods of analysis, with free and immobilized enzymes. The system with free enzymes permitted analysis of standard ethanol solution in a range of 0.05–1.0 g of ethanol/L without external dilution, a sampling frequency of 15 analyses/h, and relative SD of 3.5%. A new system was designed consisting of a microreactor with a 0.91-mL internal volume filled with alcohol oxidase immobilized on glass beads and an addition of free peroxidase, adapted in an FIA line, for continued reuse. This integrated biosensor-FIA system is being used for quality control of biofuels, gasohol, and hydrated ethanol. The FIA system integrated with the microreactor showed a calibration curve in the range of 0.05–1.5 g of ethanol/L, and good results were obtained compared with the ethanol content measured by high-performance liquid chromatography and gas chromatography standard methods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Nogueira, L. A. H. (2002), The Evolution of Fuel Quality in Brazil, 17 th World Petroleum Congress, (Website: http://www.ANP.gov.br), retrieved November 09, 2002.

  2. Szwarc, A. (2002), Ethanol Usage in Automotive Fuels, World Fuels Conference—Latin America & the Caribbean, (Website: http://www.chemweek.com/worldfuels/rio/pdf/1408_03.pdf), retrieved on October 11, 2002.

  3. Schugerl, K. (2001), J. Biotechnol. 85, 49–173.

    Article  Google Scholar 

  4. Salgado, A. M., Folly, R. O. M., Valdman, B., Cós, O., and Valero, F. (2000), Biotechnol. Lett. 22, 327–330.

    Article  CAS  Google Scholar 

  5. Sarker, A. K., Ukeda, H., Kawana, D., and Sawamura, M. (2001), Food Res. Int. 34, 393–399.

    Article  CAS  Google Scholar 

  6. Setkus, A., Razumiené, J., Galdikas, A., Laurinavicius, Meskys, R., and Mironas, A. (2002), Sens. Actuators B Chem. 85, 1–9.

    Article  Google Scholar 

  7. Tkac, J., Vostiar, I., Gorton, L., Gemeiner, P., and Sturdik, E. (2003), Biosens. Bioelectron. 18, 1125–1134.

    Article  PubMed  CAS  Google Scholar 

  8. Patel, N. G., Meier, S., Cammann, K., and Chemnitius, G. C. (2001), Sens. Actuators B Chem. 75, 101–110.

    Article  Google Scholar 

  9. Taniai, T., Sukurragawa, A., and Okitani, T. (2001), J. AOAC Int. 84(5), 1475–1483.

    PubMed  CAS  Google Scholar 

  10. Rank, M., Gram, J., and Danielsson, B. (1993), Analytica Chimica Acta 281, 521–526.

    Article  CAS  Google Scholar 

  11. Gué, A.-M., Tap, H., Gros, P., and Maury, F. (2002), Sens. Actuators B Chem. 82, 227–232.

    Article  Google Scholar 

  12. ABNT. (1997), Brazilian Association of Technical Standards, NBR 13992.

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Belkis Valdman.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Alhadeff, E.M., Salgado, A.M., Pereira, N. et al. Development and application of an integrated system for monitoring ethanol content of fuels. Appl Biochem Biotechnol 113, 125–136 (2004). https://doi.org/10.1385/ABAB:113:1-3:125

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1385/ABAB:113:1-3:125

Index Entries

Navigation