Abstract
High-performance liquid chromatography with tandem mass spectrometry has been used for rapid, specific, and sensitive analysis of busulfan in human plasma. Busulfan-d8 was used as internal standard. Analysis was performed on a C18 column (50 mm × 2.1 mm, 3.5-µm particles) with water–methanol 80:20 (v/v) as mobile phase at a flow-rate of 0.30 mL min−1. Detection was by tandem triple–quadrupole mass spectrometry with turbo ion-spray ionization. Linear calibration plots were obtained over the concentration range 1.096–1,096 ng mL−1. The assay is ideally suited to monitoring of busulfan and determination of its pharmacokinetic data.
References
Geller RB, Dix SP (1999) Drugs 58:109–118. doi:10.2165/00003495-199958003-00015
Geller RB, Vogelsang GB, Wingard JR, Yeager AM, Burns WH, Santos GW, Saral R (1988) J Clin Oncol 6:1558–1561
Nevill TJ, Shepherd JD, Reece DE, Barnett MJ, Nantel SH, Klingemann HG, Philips GL (1992) Bone Marrow Transplant 10:445–450
Slattery JT, Clift RA, Buckner CD, Radich J, Storer B, Bensinger WI, Soll E, Anasetti C, Bowden R, Bryant E, Chauncey T, Deeg HJ, Doney KC, Flowers M, Gooley T, Hansen JA, Martin PJ, Mcdonald GB, Nash R, Petersdorf EW, Sanders JE, Schorch G, Stewart P, Storb R, Appelbaum FR (1997) Blood 89:3055–3060
Galimberti M, Polchi P, Lucarelli G, Delfini C, Politi P, Giardini C, Baronciani D, Manenti F (1987) Ann NY Acad Sci 511:464–467. doi:10.1111/j.1749-6632.1987.tb36277.x
Maschan AA, Kryzanovskii OI, Yourlova MI, Skorobogatova EV, Pashanov ED, Potapova YE, Timonova LA, Bogatcheva NY, Samochatova EV, Roumjantzev AG (1997) Bone Marrow Transplant 19:385–387. doi:10.1038/sj.bmt.1700662
Ozsahin H, Le Deist F, Benkerrou M, Cavazzana-Calvo M, Gomez L, Griscelli C, Blanche S, Fischer A (1996) J Pediatr 129:238–244. doi:10.1016/S0022-3476(96)70248-2
Filipovich AH, Shapiro RS, Ramsay NK, Kim T, Blazar B, Kersey J, McGlave P (1992) Blood 80:270–276
Jones RJ, Lee KS, Beschorner WE, Vogel VG, Grochow LB, Braine HG, Vogelsang GB, Sensenbrenner LL, Santos GW, Saral R (1987) Transplantation 44:778–783. doi:10.1097/00007890-19
Mcdonald GB, Hinds MS, Fisher LD, Schoch HG, Wolford JL, Banaji M, Hardin BJ, Shulman HM, Clift RA (1993) Ann Intern Med 118:255–267
Yeager AM, Wagner JE, Graham ML (1992) Blood 80:2425–2428
Ljungman P, Hassan M, Bekassy AN, Ringden O, Oberg G (1997) Bone Marrow Transplant 20:909–913. doi:10.1038/sj.bmt.1700994
Vassal G, Fischer A, Challine D, Boland I, Ledheist F, Lemerle S, Vilmer E, Rahimy C, Souillet G, Gluckman E, Michel G, Deroussent A, Gouyette A (1993) Blood 82:1030–1034
Tran HT, Madden T, Petropoulos D, Worth LL, Felix EA, Sprigg-Saenz HA, Choroszy M, Danielson M, Przepiorka D, Chan KW (2000) Bone Marrow Transplant 26:463–470. doi:10.1038/sj.bmt.1702561
Chattergoon DS, Saunders EF, Klein J, Calderwood S, Doyle J, Freedman MH, Koren G (1997) Bone Marrow Transplant 20:347–354. doi:10.1038/sj.bmt.1700891
Hassan M, Ehrsson H (1983) J Chromatogr 277:374–380. doi:10.1016/S0378-4347(00)84861-6
Chen TL, Grochow LB, Hurowitz LA, Brun-dret RB (1988) J Chromatogr 425:303–309. doi:10.1016/0378-4347(88)80034-3
Ehrsson H, Hassan M (1983) J Pharm Sci 72:1203–1205. doi:10.1002/jps.2600721024
Vassal G, Re M, Gouyette A (1988) J Chromatogr 428:357–361. doi:10.1016/S0378-4347(00)83928-6
Henner WD, Furlong EA, Flaherty MD, Shea TC (1987) J Chromatogr 416:426–432. doi:10.1016/0378-4347(87)80531-5
Mackichan JJ, Bechtel TP (1990) J Chromatogr 532:424–428. doi:10.1016/S0378-4347(00)83794-9
Blanz J, Rasenfeld C, Proksch B, Ehninger G, Zeller KP (1990) J Chromatogr 532:429–437. doi:10.1016/S0378-4347(00)83795-0
Pichini S, Altieri I, Bacosi A, Carlo SD, Zuccaro P (1992) J Chromatogr 581:143–146. doi:10.1016/0378-4347(92)80458-3
Quernin MH, Duval M, Litalien C, Vilmer E, Aigrain EJ (2001) J Chromatogr B 763:61–69. doi:10.1016/S0378-4347(01)00356-5
Mürdter TE, Coller J, Claviez A, Schönberger F, Hofmann U, Dreger P, Schwab M (2001) Clin Chem 47:1437–1442
Kellogg MD, Law T, Sakamoto M, Rifai N (2005) Ther Drug Monit 27:625–629. doi:10.1097/01.ftd.0000173372.04945.7b
Rauh M, Stachel D, Kuhlen M, Groschl M, Holter W, Rascher W (2006) Clin Pharmacokinet 45:305–316. doi:10.2165/00003088-200645030-00006
Oliveira dos Reis E, Vianna-Jorge R, Suarez-Kurtz G, da Silva Lima EL, de Almeida Azevedo D (2005) Rapid Commun Mass Spectrom 19:1666–1674. doi:10.1002/rcm.1962
Abdel-Rehim M, Hassan Z, Skansem P, Hassan M (2007) J Liq Chromatogr Relat Technol 30:3029–3041. doi:10.1080/10826070701632337
Department of Health, Human Services Guidance for Industry (2001) Bioanalytical method validation. Food and Drug Administration, Rockville
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Chen, L., Zhou, Z., Shen, M. et al. Quantitative Analysis of Busulfan in Human Plasma by LC-MS–MS. Chroma 70, 1727–1732 (2009). https://doi.org/10.1365/s10337-009-1352-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1365/s10337-009-1352-0