Abstract
The reliability of evaluation of compound purity depends on the analytical method selected. A suitable analytical method, including the modes of separation and detection, can provide reliable information about compound purity. Effective separation is the key to achieving precise results. In this work we developed a novel method, based on an orthogonal system, RP-LC-hydrophilic interaction liquid chromatography, for evaluating the purity of compounds isolated by preparative reversed-phase liquid chromatography. Because of its good orthogonality, good separation and more accurate assessment of compound purity could be achieved.
Similar content being viewed by others
References
Görög S, Babják M, Balogh G, Brlik J, Csehi A, Dravecz F, Gazdag M, Horvát D, Laukó A, Varga K (1997) Talanta 44:1517–1526. doi:10.1016/S0039-9140(96)02179-0
Krska R, Schothorst R, van Egmond HP, Josephs RD, Lepschy J, Pettersson H, Chan D, Berthiller F, Schuhmacher R, Dandler W, Parich A, Welzig E (2005) Anal Bioanal Chem 382:1848–1858. doi:10.1007/s00216-005-3330-1
Argentine MD, Owens PK, Olsen BA (2007) Adv Drug Deliv Rev 59:12–28. doi:10.1016/j.addr.2006.10.005
Fang LL, Pan JM, Yan B (2001) Biotechnol Bioeng 71:162–171. doi:10.1002/1097-0290(2000)71:2<162::AID-BIT1006>3.0.CO;2-A
Mathews BT, Higginson PD, Lyons R, Mitchell JC, Sach NW, Snowden MJ, Taylor MR, Wright AG (2004) Chromatographia 60:625–633. doi:10.1365/s10337-004-0441-3
Molina-Martin M, Marin A, Rivera-Sagredo A, Espada A (2005) J Sep Sci 28:1742–1750. doi:10.1002/jssc.200500107
Visky D, Jimidar I, Ael WV, Vennekens T, Redlich D, Smet MD (2005) Electrophoresis 26:1541–1549. doi:10.1002/elps.200410225
Babják M, Balogh G, Gazdag M, Görög S (2002) J Pharm Biomed 29:1153–1157. doi:10.1016/S0731-7085(02)00165-6
Yasueda S, Higashiyama M, Shirasaki Y, Inada K, Ohtori A (2004) J Pharm Biomed 36:309–316. doi:10.1016/j.jpba.2004.06.006
Guo ZM, Lei AW, Zhang YP, Xu Q, Xue XY, Zhang FF, Liang XM (2007) Chem Commun (Camb) 24:2491–2493. doi:10.1039/b701831b
Yan B, Collins N, Wheatley J, Irving M, Leopold K, Chan C, Shornikov A, Fang LL, Lee A, Stock M, Zhao J (2004) J Comb Chem 6:255–261. doi:10.1021/cc0340527
Guo ZM, Jin Y, Liang T, Liu YF, Xu Q, Liang XM, Lei AW (2009) J Chromatogr A 1216:257–263. doi:10.1016/j.chroma.2008.11.071
Acknowledgment
This work was supported by the “Science and Technology Plan of Liaoning Province (2006226002)”, the “National Natural Science Funds (20775079)”, and “Programs Funded by Ministry of Science and Technology of China During the 11th Five-Year Plan (2006BAI06A01-06)”.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Wang, Y., Zhang, F., Xue, X. et al. Use of an Orthogonal System, RP-LC–HILIC, for Evaluation of Purity. Chroma 69, 1379–1384 (2009). https://doi.org/10.1365/s10337-009-1077-0
Received:
Revised:
Accepted:
Published:
Issue Date: