Skip to main content
Log in

Use of an Orthogonal System, RP-LC–HILIC, for Evaluation of Purity

  • Full Short Communication
  • Published:
Chromatographia Aims and scope Submit manuscript

Abstract

The reliability of evaluation of compound purity depends on the analytical method selected. A suitable analytical method, including the modes of separation and detection, can provide reliable information about compound purity. Effective separation is the key to achieving precise results. In this work we developed a novel method, based on an orthogonal system, RP-LC-hydrophilic interaction liquid chromatography, for evaluating the purity of compounds isolated by preparative reversed-phase liquid chromatography. Because of its good orthogonality, good separation and more accurate assessment of compound purity could be achieved.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Görög S, Babják M, Balogh G, Brlik J, Csehi A, Dravecz F, Gazdag M, Horvát D, Laukó A, Varga K (1997) Talanta 44:1517–1526. doi:10.1016/S0039-9140(96)02179-0

    Article  Google Scholar 

  2. Krska R, Schothorst R, van Egmond HP, Josephs RD, Lepschy J, Pettersson H, Chan D, Berthiller F, Schuhmacher R, Dandler W, Parich A, Welzig E (2005) Anal Bioanal Chem 382:1848–1858. doi:10.1007/s00216-005-3330-1

    Article  CAS  Google Scholar 

  3. Argentine MD, Owens PK, Olsen BA (2007) Adv Drug Deliv Rev 59:12–28. doi:10.1016/j.addr.2006.10.005

    Article  CAS  Google Scholar 

  4. Fang LL, Pan JM, Yan B (2001) Biotechnol Bioeng 71:162–171. doi:10.1002/1097-0290(2000)71:2<162::AID-BIT1006>3.0.CO;2-A

    Article  CAS  Google Scholar 

  5. Mathews BT, Higginson PD, Lyons R, Mitchell JC, Sach NW, Snowden MJ, Taylor MR, Wright AG (2004) Chromatographia 60:625–633. doi:10.1365/s10337-004-0441-3

    Article  CAS  Google Scholar 

  6. Molina-Martin M, Marin A, Rivera-Sagredo A, Espada A (2005) J Sep Sci 28:1742–1750. doi:10.1002/jssc.200500107

    Article  CAS  Google Scholar 

  7. Visky D, Jimidar I, Ael WV, Vennekens T, Redlich D, Smet MD (2005) Electrophoresis 26:1541–1549. doi:10.1002/elps.200410225

    Article  CAS  Google Scholar 

  8. Babják M, Balogh G, Gazdag M, Görög S (2002) J Pharm Biomed 29:1153–1157. doi:10.1016/S0731-7085(02)00165-6

    Article  Google Scholar 

  9. Yasueda S, Higashiyama M, Shirasaki Y, Inada K, Ohtori A (2004) J Pharm Biomed 36:309–316. doi:10.1016/j.jpba.2004.06.006

    Article  CAS  Google Scholar 

  10. Guo ZM, Lei AW, Zhang YP, Xu Q, Xue XY, Zhang FF, Liang XM (2007) Chem Commun (Camb) 24:2491–2493. doi:10.1039/b701831b

    Article  Google Scholar 

  11. Yan B, Collins N, Wheatley J, Irving M, Leopold K, Chan C, Shornikov A, Fang LL, Lee A, Stock M, Zhao J (2004) J Comb Chem 6:255–261. doi:10.1021/cc0340527

    Article  CAS  Google Scholar 

  12. Guo ZM, Jin Y, Liang T, Liu YF, Xu Q, Liang XM, Lei AW (2009) J Chromatogr A 1216:257–263. doi:10.1016/j.chroma.2008.11.071

    Article  CAS  Google Scholar 

Download references

Acknowledgment

This work was supported by the “Science and Technology Plan of Liaoning Province (2006226002)”, the “National Natural Science Funds (20775079)”, and “Programs Funded by Ministry of Science and Technology of China During the 11th Five-Year Plan (2006BAI06A01-06)”.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Xinmiao Liang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Wang, Y., Zhang, F., Xue, X. et al. Use of an Orthogonal System, RP-LC–HILIC, for Evaluation of Purity. Chroma 69, 1379–1384 (2009). https://doi.org/10.1365/s10337-009-1077-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1365/s10337-009-1077-0

Keywords

Navigation