Abstract
The present study was carried out to evaluate the precision and to identify significant sources of variability in flash pyrolysis-GC-MS experiments. The analysis of variance has been applied to the example of polyethylene pyrolysis to estimate the impact of several controlled factors: sample handling, flash pyrolysis filament ageing and calibration. It was demonstrated that to get the best precision in experimental results, it is recommended to set the operator to reduce the impact of sample handling procedure and the filament to avoid variability due to changes in filament characteristics. In comparison, filament ageing and filament calibration are shown to influence in a limited extent the experimental results.



Similar content being viewed by others
Explore related subjects
Discover the latest articles and news from researchers in related subjects, suggested using machine learning.References
Tsuge S (1995) J Anal Appl Pyrolysis 32:1. doi:10.1016/0165-2370(94)00852-R
Blazso M (1997) J Anal Appl Py 39:1. doi:10.1016/S0165-2370(96)00956-4
Bart JCJ (2001) J Anal Appl Pyrolysis 3:58–59. doi:10.1016/S0165-2370(00)00160-1
Haken JK (1998) J Chrom A 825:171. doi:10.1016/S0021-9673(98)00607-4
Wampler TP (1999) J Chrom A 842:207. doi:10.1016/S0021-9673(98)00921-2
Mestdagh H, Rolando C, Sablier M, Rioux JP (1992) Anal Chem 64:2221. doi:10.1021/ac00043a007
Westerhout RWJ, Waanders J, Kuipers JAM, van Swaaij WPM (1997) Ind Eng Chem Res 36:1955. doi:10.1021/ie960501m
Lavine BK, Moores A, Helfend LK (1999) J Anal Appl Pyrolysis 50:47. doi:10.1016/S0165-2370(99)00002-9
Jarde E, Vilmin F, Mansuy L, Faure P (2004) J Anal Appl Pyrolysis 71:553. doi:10.1016/j.jaap.2003.08.008
Goodacre R, Hammond D, Kell DB (1997) J Anal Appl Pyrolysis 40–41:135. doi:10.1016/S0165-2370(96)00973-4
Causin V, Marega C, Schiavone S, Della Guardia V, Marigo A (2006) J Anal Appl Pyrolysis 75:43. doi:10.1016/j.jaap.2005.04.009
Meier D, Fortmann I, Odermatt J, Faix O (2005) J Anal Appl Pyrolysis 74:129. doi:10.1016/j.jaap.2004.12.001
Wilcken H, Schulten H-R (1996) Fresenius J Anal Chem 335:157
Nordmark UJ (2000) Anal Appl Pyrolysis 55:93. doi:10.1016/S0165-2370(99)00093-5
Vekey K, Tamas J, Somogyi A, Bertazzo A, Costa C, Allegri G, Seraglia R, Tardi P (1992) Org Mass Spectrom 27:1216. doi:10.1002/oms.1210271111
Grimbley MR, Lehrle RS, Williams RJ, Bate DM (1995) Polym Degrad Stabil 48:143. doi:10.1016/0141-3910(95)00009-B
Hickman DA, Jane I (1979) Analyst (Lond) 104:334. doi:10.1039/an9790400334
Stankiewicz BA, van Bergen PF, Smith MB, Carter JF, Briggs DEG, Evershed RP (1998) J Anal Appl Pyrolysis 45:133. doi:10.1016/S0165-2370(98)00064-3
Wampler TP, Levy EJ (1987) J Anal Appl Pyrolysis 12:75. doi:10.1016/0165-2370(87)85058-1
Anderson EM, Ericsson I (1981) J Anal Appl Pyrolysis 3:35. doi:10.1016/0165-2370(81)80024-1
Dawes PA, Cumbers MK, Hilling PA (1988) J High Res Chrom 11:328. doi:10.1002/jhrc.1240110406
ICH4 (1996) “Validation of analytical procedure: Methodology, Q2B, ICH Steering Comitee, London
Vial J, Jardy A (2001) Chromatographia Suppl 53:S141. doi:10.1007/BF02490320
Miller JC, Miller JN (1993) In: Horwood E (ed) Statistics for analytical chemistry, 3rd edn. PTR Prentice Hall, New York
Massard DL, Vandeginste BGM, Buydens LMC, De Jong S, Lewi PJ, Smeyers-Verbeke J (eds) (1997) In: Handbook of chemometrics and qualimetrics: part A, Elsevier, Amsterdam, p 121
Jardy A, Vial J (1999) Analusis 27:511. doi:10.1051/analusis:1999270511
Vial J, Jardy A, Anger P, Brun A, Menet JM (1998) J Chromatogr A 815:173. doi:10.1016/S0021-9673(98)00510-X
Ji L, Hervier A, Sablier M (2006) Chemosphere 65:1120. doi:10.1016/j.chemosphere.2006.04.029
Massard DL, Vandeginste BGM, Buydens LMC, De Jong S, Lewi PJ, Smeyers-Verbeke J (eds) (1997) In: Handbook of chemometrics and qualimetrics: part A, Elsevier, Amsterdam, p 132
Poustma ML (2003) Macromolecules 36:8931. doi:10.1021/ma0303768
Levy RL, Fanter DL, Wolf CJ (1972) Anal Chem 44:38. doi:10.1021/ac60309a008
Andersson EM, Ericsson I (1979) J Anal Appl Pyrolysis 1:27. doi:10.1016/0165-2370(79)80003-0
Massard DL, Vandeginste BGM, Buydens LMC, De Jong S, Lewi PJ, Smeyers-Verbeke J (eds) (1997) In: Handbook of chemometrics and qualimetrics: part A, Elsevier, Amsterdam, p 95
Levy EJ, Walker JQ (1984) J Chromatogr Sci 22:49
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ji, L., Riana, L.P., Sablier, M. et al. Precision of Flash Pyrolysis-GC-MS Analysis: Experimental Evaluation of the Sources of Variability. Chroma 69, 691–699 (2009). https://doi.org/10.1365/s10337-009-0965-7
Received:
Revised:
Accepted:
Published:
Issue Date: