Skip to main content
Log in

Simple, Sensitive and Rapid LC–ESI–MS Method for the Quantitation of Olprinone in Rat Plasma

  • Original
  • Published:
Chromatographia Aims and scope Submit manuscript

Abstract

Olprinone is a phosphodiesterase (PDE)-3 inhibitor. This paper describes a simple, selective and sensitive method for the quantification of olprinone in rat plasma using a liquid–liquid extraction procedure followed by liquid chromatography mass spectrometric (LC–MS) analysis. The method had an advantage of high sensitivity. Analyses were conducted at a flow rate of 0.25 mL min−1 by a gradient elution. The detection utilized selected ion monitoring in the positive ion mode at m/z 251.0 and 344.0 for the protonated molecular ions of olprinone and the internal standard, respectively. The quantitation limit for olprinone in rat plasma was 0.5 ng mL−1. The linearity was also excellent over the concentration range of 0.5–100 ng mL−1 of olprinone. The intra- and inter-day precision (relative standard deviation (RSD) %) was lower than 10%, and accuracy ranged from 90 to 110%. This developed method was successfully applied to analysis of olprinone in biological fluids.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+
from $39.99 /Month
  • Starting from 10 chapters or articles per month
  • Access and download chapters and articles from more than 300k books and 2,500 journals
  • Cancel anytime
View plans

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Miyabe M, Tajima K, Takahashi H, Toyooka H (2003) Can J Anesth 50:193–197

    Article  Google Scholar 

  2. Uemura A, Fujii Y, Toyooka H (2002) Br J Anaesth 88:408–411

    Article  CAS  Google Scholar 

  3. Satoh T, Morisaki H, Ai K, Kosugi S, Yamamoto M, Serita R,Kotake Y, Takeda J (2003) Anesthesiology 98:1407–1414

    Article  CAS  Google Scholar 

  4. Mizutani A, Murakami K, Okajima K, Kira S, Mizutani S, Kudo K, Takatani J, Goto K,Hattori S, Noguchi T (2005) Shock 24:281–287

    Article  CAS  Google Scholar 

  5. Iwade M, Nomura M, Uezono S, Ashikari E, Ozaki M (2006) J Cardiothorac Vasc Anesth 20:358–363

    Article  CAS  Google Scholar 

  6. Ueda T, Mizushige K, Yukiiri K, Takahashi T, Kohno M (2003) Cerebrovasc Dis 16:396–401

    Article  CAS  Google Scholar 

  7. Amenomori H, Sasaki S, Hiraoka K, Morimoto Y, Gando S, Kemmotsu O (2000) Asaio J 10:635–638

    Article  Google Scholar 

  8. Guidance for Industry, Bioanalytical Method Validation, US Department of Health and Human Services, Food and Drug Administration, Center for Drug Evaluation and Research (CDER) 2001

Download references

Author information

Authors and Affiliations

Corresponding author

Correspondence to Guang-Ji Wang.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sun, J., Liang, Y., Xie, L. et al. Simple, Sensitive and Rapid LC–ESI–MS Method for the Quantitation of Olprinone in Rat Plasma. Chroma 66, 49–54 (2007). https://doi.org/10.1365/s10337-007-0262-2

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1365/s10337-007-0262-2

Keywords