Abstract
A method for the determination of anethole in aniseed drinks by high performance liquid chromatography (HPLC) is proposed. A C-18 column and a methanol-water (80:20, v/v) mobile phase with isocratic elution were used. UV detection at 257 nm was carried out. Validation was performed according to the EURACHEM guidelines, considering precision, trueness, robustness, linearity and sensitivity. The detection and quantification limits were 2.3 and 7.7 μg L−1, respectively. Recoveries of 95–101% were obtained. Repeatability, calculated as relative standard deviation was 0.9%. Reproducibility under intermediate precision conditions, expressed as relative standard deviation, was 1.6%. The method was compared with the gas chromatographic one, proposed by the European regulations.
Similar content being viewed by others
References
González MJ, Martínez MC, Aguilar MV (1988) Z Lebens Unters Forsch 187:325–329
Andrea V, Nadia N, Teresa RM, Andrea A (2003) J Agric Food Chem 51:4978–4983
Diéguez SC, Peña MLG, Gómez EF (2003) J Agric Food Chem 51:7385–7390
Directive (CEE) No 1576/89. Off J Eur Commun L160 (12–6–1989)
Besharati-Seidani A, Jabbari A, Yamini Y (2005) Anal Chim Acta 530:155–161
Rodrigues VM, Rosa PTV, Marques MOM, Petenate AJ, Meireles MAA (2003) J Agric Food Chem 51:1518–1523
Regulation (EC) No 2091/2002. Off J Eur Commun L322 (26–11–2002)
Brereton P, Hasnip S, Bertrand A, Wittkowski C, Guillou C (2003) Trends Analyt Chem 22:19–25
Snyder LR, Kirkland JJ, Glajch JL (1997) Practical HPLC method development. Wiley, New York
EURACHEM (1998) The fitness for purpose of analytical method: a laboratory guide to method validation and related topics, http://www.eurachem.ul.pt
Maroto A, Boqué R, Riu J, Rius FX (2001) Anal Chim Acta 440:171–184
González AG, Herrador MA, Asuero AG (1999) Talanta 48:729–736
Miller JN, Miller JC (2000) Statistics and chemometrics for analytical chemistry, 4th edn. Prentice-Hall, London
Passing H, Bablock JA (1983) J Clin Chem Biochem 21:709–720
Youden WJ (1967) Statistical techniques for collaborative test. AOAC, Washington
González AG, Herrador MA, Asuero AG (2005) Talanta 65:1022–1030
Placket RL, Burmann JP (1946) Biometrica 33:305–325
Huber L (1998) LC-GC Int 11:96–105
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Jurado, J.M., Alcázar, A., Pablos, F. et al. LC Determination of Anethole in Aniseed Drinks. Chroma 64, 223–226 (2006). https://doi.org/10.1365/s10337-006-0001-0
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1365/s10337-006-0001-0